Chapter 1
Process Control Instructions
228 Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Output
Parameters
Data
Type
Description Values
CV2PV2GainTuned REAL The calculated value of the internal model gain for
CV2 - PV2 after tuning is completed.
CV3PV2GainTuned REA: The calculated value of the internal model gain for
CV3 - PV2 after tuning is completed.
CV1PV1TCTuned REAL The calculated value of the internal model time
constant for CV1 - PV1 after tuning is completed.
CV2PV1TCTuned REAL The calculated value of the internal model time
constant for CV2 - PV1 after tuning is completed.
CV3PV1TCTuned REAL The calculated value of the internal model time
constant for CV3 - PV1 after tuning is completed.
CV1PV2TCTuned REAL The calculated value of the internal model time
constant for CV1 - PV2 after tuning is completed.
CV2PV2TCTuned REAL The calculated value of the internal model time
constant for CV2 - PV2 after tuning is completed.
CV3PV2TCTuned REAL The calculated value of the internal model time
constant for CV3 - PV2 after tuning is completed.
CV1PV1DTTuned REAL The calculated value of the internal model
deadtime for CV1 - PV1 after tuning is completed.
CV2PV1DTTuned REAL The calculated value of the internal model
deadtime for CV2 - PV1 after tuning is completed.
CV3PV1DTTuned REAL The calculated value of the internal model
deadtime for CV3 - PV1 after tuning is completed.
CV1PV2DTTuned REAL The calculated value of the internal model
deadtime for CV1 - PV2 after tuning is completed.
CV2PV2DTTuned REAL The calculated value of the internal model
deadtime for CV2 - PV2 after tuning is completed.
CV3PV2DTTuned REAL The calculated value of the internal model
deadtime for CV3 - PV2 after tuning is completed.
CV1PV1RespTCTun
edS
REAL The calculated value of the control variable time
constant in slow response speed for CV1 - PV1 after
tuning is completed.
CV2PV1RespTCTun
edS
REAL The calculated value of the control variable time
constant in slow response speed for CV2 - PV1 after
tuning is completed.
CV3PV1RespTCTun
edS
REAL The calculated value of the control variable time
constant in slow response speed for CV3 - PV1 after
tuning is completed.
CV1PV2RespTCTun
edS
REAL The calculated value of the control variable time
constant in slow response speed for CV1 - PV2 after
tuning is completed.
CV2PV2RespTCTun
edS
REAL The calculated value of the control variable time
constant in slow response speed for CV2 - PV2 after
tuning is completed.
CV3PV2RespTCTun
edS
REAL The calculated value of the control variable time
constant in slow response speed for CV3 - PV2 after
tuning is completed.
CV1PV1RespTCTun
edM
REAL The calculated value of the control variable time
constant in medium response speed for CV1 - PV1
after tuning is completed.