Bulletin 900-TC8 and 900-TC16
Global Temperature (Thermocouple/RTD) and Analog Ranges and Selections
10
Temperature Sensor Input Ranges (In Degrees C)
Controllers with Analog Inputs
Input Type Current Voltage
Input Specification 4...20 mA 0...20 mA 1...5V DC 0...5V DC 0...10V DC
Setting Range
Usable in the following ranges by scaling:
-1999...9999, -199.9...999.9, -19.99...99.99 or -1.999...9.999
Setting Number 01234
Shaded area is the default setting for analog input type (AB) 900-TC8xAB or 900-TC16xAB controllers.
Bulletin 900-TC8 and 900-TC16
Input
type
Platinum resistance
thermometer
Thermocouple
Infrared temperature
sensor
Analog
input
Name Pt100 JPt100 K J T E L U N R S B W
PL
II
10 to
70°C
60 to
120
°C
115
to
165
°C
140
to
260
°C
0 to
50 mV
Temperature range (°C)
2300
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
100.0
200.0
2300
Usable
in the
following
ranges
by
scaling:
1999 to
9999 or
199.9
to 999.9
1800
1700 1700
003100310031
058058058
600
500.0 500.0 500.0
400.0 400 400.0 400 400.0
260
120 165
100.0 100.0 90
100
0.0 0.0 00 00 0 0 0 0
20.0 100 20.0 100
200 199.9 199.9 200 200 199.9 200 200 199.9 200
Setting
number
01234
5 6 7 8 9 1011121314151617182425 19 20 21 22 23
900-TC8 and 900-TC16 Input Ranges
9 Applicable standards by input type are as follows:
K, J, T, E, N, R, S, B: JIS C1602-1995
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W:W5Re/W26Re, ASTM E998-1990
PLII: According to Platinel ll electromotive force charts from BASF (previously Engelhard)
7 JPt100: JIS C1604-1989, JIS C1606-1989
Pt100: JIS C1604-1997, IEC 751
The non-contact temperature sensor must be configurable for type K thermocouple output within either of the four specified ranges. For example, an OMRON
ES1A or Calex EL Series (Convir) infrared sensor.
§ Shaded setting number indicates default setting for thermocouple or platinum RTD type 900-TC8xGT or 900-TC16xGT controllers.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Bulletin 900-TC Series and is the answer not in the manual?

Allen-Bradley Bulletin 900-TC Series Specifications

General IconGeneral
BrandAllen-Bradley
ModelBulletin 900-TC Series
CategoryController
LanguageEnglish

Related product manuals