Page #81 background imageLoading...
Page #81 background image
Rockwell Automation Publication 520-UM001G-EN-E - September 2014 81
Programming and Parameters Chapter 3
Basic Program Group (continued)
P053 [Reset To Defalts]
Stop drive before changing this parameter.
Resets all parameters to their factory default values. After a Reset command, the value of this parameter returns to zero.
Options 0 “Ready/Idle” (Default)
1 “Param Reset” Does not reset custom groups, parameter P030 [Language], and communication parameters.
2 “Factory Rset” Restore drive to factory condition.
3 “Power Reset” Resets only power parameters. Can be used when swapping power modules.
Parameters that are Reset when P053 = 3
Parameter Name
P031 [Motor NP Volts]
P033 [Motor OL] Current
P034 [Motor NP FLA]
P035 [Motor NP Poles]
P038 [Voltage Class]
A435 [DC Brake Level]
A484 [Current Limit 1]
A485 [Current Limit 2]
A486 [Shear Pin1 Level]
A488 [Shear Pin2 Level]
A490 [Load Loss Level]
A496 [IR Voltage Drop]
A497 [Flux Current Ref]
A530 [Boost Select]
A531 [Start Boost]
A532 [Break Voltage]
A533 [Break Frequency]
A534 [Maximum] Voltage
Parameters that are NOT Reset when P053 = 1
Parameter Parameter Parameter
P030 [Language] C138 [EN Gateway Cfg 2] C159 [EN Data Out 3]
C121 [Comm Write Mode] C139 [EN Gateway Cfg 3] C160 [EN Data Out 4]
C122 [Cmd Stat Select] C140 [EN Gateway Cfg 4] C161 [Opt Data In 1]
C123 [RS485 Data Rate] C141 [EN Rate Cfg] C162 [Opt Data In 2]
C124 [RS485 Node Addr] C143 [EN Comm Flt Actn] C163 [Opt Data In 3]
C124 [Comm Loss Action] C144 [EN Idle Flt Actn] C164 [Opt Data In 4]
C126 [Comm Loss Time] C145 [EN Flt Cfg Logic] C165 [Opt Data Out 1]
C127 [RS485 Format] C146 [EN Flt Cfg Ref] C166 [Opt Data Out 2]
C128 [EN Addr Sel] C147 [EN Flt Cfg DL 1] C167 [Opt Data Out 3]
C129 [EN IP Addr Cfg 1] C148 [EN Flt Cfg DL 2] C168 [Opt Data Out 4]
C130 [EN IP Addr Cfg 2] C149 [EN Flt Cfg DL 3] C169 [MultiDrv Sel]
C131 [EN IP Addr Cfg 3] C150 [EN Flt Cfg DL 4] C171 [Drv 1 Addr]
C132 [EN IP Addr Cfg 4] C153 [EN Data In 1] C172 [Drv 2 Addr]
C133 [EN Subnet Cfg 1] C154 [EN Data In 2] C173 [Drv 3 Addr]
C134 [EN Subnet Cfg 2] C155 [EN Data In 3] C174 [Drv 4 Addr]
C135 [EN Subnet Cfg 3] C156 [EN Data In 4] C175 [DSI I/O Cfg]
C136 [EN Subnet Cfg 4] C157 [EN Data Out 1] GC [Parameters in Custom Group]
C137 [EN Gateway Cfg 1] C158 [EN Data Out 2]

Table of Contents

Questions and Answers: