Installation/Operation/Maintenance
Tumble Dryers
50 Pound (25 Kilogram) Capacity
75 Pound (34 Kilogram) Capacity
Starting Serial No. 0904004427
Refer to Page 9 for Model Identification
TMB1277C_SVG
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No: 70457901ENR15
June 2017

Table of Contents

Questions and Answers

  • P
    Peter WaltersJul 31, 2025
    What to do if there is valve on, no spark during TFI in Alliance Laundry Systems 0904004427?
    • B
      Bradley CannonJul 31, 2025
      If the Alliance Laundry Systems Dryer shows a valve on but no spark during TFI (Trial For Ignition), several issues could be at play. First, examine the electrode for any shorts. Second, ensure the spark gap is correctly set between 0.094 and 0.156 inches. Next, inspect the high voltage cable for any faults or poor connections. Finally, check for a control failure.
  • C
    christophermillerAug 4, 2025
    What to do if Alliance Laundry Systems 0904004427 Dryer has spark on, but no flame?
    • B
      brian45Aug 4, 2025
      If your Alliance Laundry Systems Dryer exhibits a spark but no flame, start by verifying that the gas supply is turned on. Next, check for 24 VAC at the gas valve. If both are present, check the voltage between the gas valve terminal MV and GND on the control to rule out a bad control.
  • N
    Nancy ThompsonAug 8, 2025
    What to do if Alliance Laundry Systems Dryer flame okay during TFI, no flame sense after TFI?
    • M
      Melinda SmithAug 8, 2025
      If the Alliance Laundry Systems Dryer has flame okay during TFI, but no flame sense after TFI, you should check the electrode position and ensure it's clean. Also, inspect the high voltage wire. Another potential cause is a poor ground at the burner, or a poor flame, so check the flame current.
  • R
    Ronald PhillipsAug 13, 2025
    What to do if thermostat on, no spark or valve in Alliance Laundry Systems 0904004427?
    • G
      Gregory RiversAug 13, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, verify the cable connections to both the control and the electrode, and check for voltage at the gas valve. Also, check the red LED for steady on or flashing codes, which may indicate a bad control.
  • K
    krichardAug 17, 2025
    How to reset Alliance Laundry Systems 0904004427 control in lockout mode?
    • J
      Jerome MillerAug 17, 2025
      If the Alliance Laundry Systems Dryer control is in lockout mode, you need to manually reset it by pushing the red lockout button or using the front end control.
  • R
    Robert MartinAug 21, 2025
    Why Alliance Laundry Systems 0904004427 control does not start, green LED is off?
    • L
      Lindsay YangAug 21, 2025
      If the Alliance Laundry Systems Dryer control does not start and the green LED is off, check for 24 VAC between 24V and ground on the 70458701 control. Also, check for 24 VAC between TH and ground.
  • A
    Amanda RamirezAug 26, 2025
    What to do if Alliance Laundry Systems Dryer has reset failure?
    • T
      Thomas WellsAug 26, 2025
      If you experience a reset failure on your Alliance Laundry Systems Dryer, try to reset it again. If the issue persists, the reset switch may be shorted, requiring a replacement.

Summary

Installation;Operation;Maintenance

Introduction

Model Identification

Details applicable models and serial plate reference for identification.

Safety Information

Important Safety Instructions

Provides essential safety precautions for operating the tumble dryer.

Installation

Pre-Installation Inspection

Covers initial checks and tasks before installing the dryer.

Fire Suppression System (Optional Equipment)

Instructions and requirements for installing the optional fire suppression system.

Electrical Requirements

Outlines the necessary electrical supply and connections for the dryer.

Exhaust Requirements

Gas Requirements

Electrical Requirements

Grounding Instructions

Details on proper electrical grounding procedures for safety.

Steam Requirements

Single Drop Timer

Error Codes

Lists error codes, definitions, and corrective actions.

Operating Instructions

Ignition Control Operation and Troubleshooting for Models Starting 3;11;13

Troubleshooting

Provides troubleshooting steps for ignition control issues.

Adjustments

Maintenance

Before You Call for Service