Continued from
previous page
Gas Models: Are gas
valve coils
inoperative?
Gas Models: Is sensor
inoperative?
No
Test coils and
replace if
inoperative. Refer to
Dryer Test Procedures
section.
Yes
Gas Models: Is
igniter inoperative?
No
Test sensor and
replace if
inoperative.
Yes
Gas Models: Is
harness properly
connected to gas
controls?
No
Test igniter and
replace if
inoperative. Refer to
Dryer Test Procedures
section.
Yes
Gas Models: Is gas
flow in gas orifice
restricted?
Yes
Check harness
connections to gas
valve coils, sensor
and main harness.
Reconnect as required.
No
Is cycling thermostat
inoperative?
No
Clean out gas orifice.
Yes
Is timer/ electronic
control noperative?
No
Test thermostat and
replace if
inoperative.
Yes
Is wiring broken,
loose or incorrect?
No
Test timer/electronic
control and replace
if inoperative.
Yes
Refer to wiring
diagram.
Yes
Troubleshooting Flowcharts
©