EasyManua.ls Logo

Alliance Laundry Systems ADE3SRGS175TW01 - Igniter Glows but Burner Does Not Ignite (Gas Dryer Models)

Alliance Laundry Systems ADE3SRGS175TW01
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Igniter Glows but Burner Does Not Ignite (Gas Dryer Models)
Did sensor fail in
closed position?
Is secondary coil or
holding coil open?
No
Replace sensor.
Yes
Is gas supply
insufficient?
No
Replace gas valve (in
warranty) or replace
coils (out of
warranty). Refer to
Dryer Test Procedures
section
Yes
Are igniter and
bracket improperly
installed on burner
tube assembly?
No
Check gas supply and
pressure. Make sure
gas shutoff valve is
turned on.
Yes
Is sensor improperly
installed on burner
housing?
No
Loosen screw and
properly position
igniter and bracket
on burner tube
assembly.
Yes
Loosen screw and
properly position the
sensor on the burner
housing.
Yes
Troubleshooting Flowcharts
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
24 Part No. D515517ENR3

Table of Contents