Dryer Heating Assembly Does Not Heat or Burner Does Not Ignite
Is exhaust system
improper or
inadequate?
Is exhaust duct made
of plastic or thin
foil?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Is house fuse blown
or circuit breaker
tripped?
No
Replace with rigid or
semirigid metal
exhaust duct.
Yes
Is temperature No
selector switch set
at FLUFF, or
inoperative?
No
Check fuses or
circuit breakers.
Yes
Is timer/ electronic
control improperly
set (set in a
cool-down period, or
a no heat cycle)?
No
Reset or test switch
and replace if
inoperative.
Yes
Is limit thermostat
inoperative?
No
Reset
timer/electronic
control. Try another
cycle.
Yes
Is drive motor switch
inoperative?
No
Test thermostat and
replace if
inoperative.
Yes
Electric Models: Is
heater assembly
inoperative?
No
Test switch and
replace if
inoperative.
Yes
Electric Models: Is
thermal fuse
inoperative?
No
Test heater assembly
and replace if cold
Ohms do not read
between 9 and 10.5
Ohms.
Yes
Gas Models: Is gas
supply insufficient?
No
Test thermal fuse and
replace if
inoperative.
Yes
Check gas shut-off
valve in dryer and
main gas line valve.
Open partially closed
gas shut-off valve or
correct low gas
pressure.
Yes
Continued on