806221 23
Dryer Control Troubleshooting
(continued)
Display Description Cause/Corrective Action
 Brownout/voltage configuration error:
Unexpected supply voltage.
Check the harness connections between the user
control and the output board. If the user control was
replaced, set dipswitch #1 to the same setting as the
previous control. If reworking the machine to use a
different supply voltage, the dip switch #1 setting may
need to be changed. If the dip switch #1 setting is
changed, power down machine, power up and try
again.
 Board ID error: Incorrect replacement
control.
Terminate cycle. Replace user control or output board
with correct part. Power down machine to clear.