EasyManua.ls Logo

Alliance Laundry Systems PA20 X CONTROL - Electrical Specifications - Models Outside of North America

Alliance Laundry Systems PA20 X CONTROL
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical Specifications - Models Outside of North America
7.5 kg / 20 lb. / 75 L Models
Voltage (V)
Frequency (Hz)
Phase
Wire
Standard Electric Heat
Total Power (kW)
Full Load Amps (A)
Fuse (A)
Total Power (kW)
Full Load Amps
(Electric Heating kW)
Fuse (A)
120 60 1 2 0.6 8 10 N/A N/A N/A
200-240 50/60 1 2 (L1, L2,
or L1, N)
0.6 4.4 10 3.4 17 (3) 20
5 24 (4.6) 32
200-240 50/60 3 3 (L1, L2,
L3)
0.6 4.4 10 6.5 19.1 (6) 25
9.5 26.5 (9) 32
380-415
+ N
50/60 3 4 (L1, L2,
L3, N)
0.6 4.4 10 5.1 10 (4.6) 16
6.5 12.6 (6) 16
9.5 17 (9) 20
380-415 50/60 3 3 (L1, L2,
L3)
0.6 2.6 10 6.5 11.7 (6) 16
9.5 16.2 (9) 20
440-480 50/60 3 3 (L1, L2,
L3)
0.6 2.6 10 7.5 13.5 (7) 16
9.5 15.5 (9) 16
Table 20
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
55 Part No. D1599ENR16

Table of Contents

Other manuals for Alliance Laundry Systems PA20 X CONTROL

Related product manuals