What to do if Alliance Laundry Systems Dryer has spark but no flame?
L
Lisa HeathAug 3, 2025
If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
D
Daniel Higgins MDAug 7, 2025
Why Alliance Laundry Systems UT055N Dryer valve is on but there is no spark during TFI?
D
dcisnerosAug 8, 2025
If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
A
Alexandra BartonAug 12, 2025
What to do if Alliance Laundry Systems Dryer flame is okay during TFI, but no flame sense after TFI?
T
Tracy SnyderAug 12, 2025
If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.
K
kaylabatesAug 16, 2025
How to fix reset failure on Alliance Laundry Systems UT055N Dryer?
A
Andrew WilsonAug 16, 2025
If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
S
Stephen SmithAug 20, 2025
What to do if Alliance Laundry Systems UT055N thermostat is on, but there is no spark or valve?
M
matthew01Aug 21, 2025
If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
J
Joshua KaneAug 25, 2025
How to reset Alliance Laundry Systems Dryer control in lockout mode?
J
Jonathan OsbornAug 26, 2025
If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
M
moorejosephAug 29, 2025
What to do if the Alliance Laundry Systems UT055N Dryer control is in lockout mode?
N
Nathaniel SinghAug 29, 2025
If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.