Programming
11
9002101
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Chemical Hold Feature
Chemical supply injection can be paused. Refer to
Setup of Chemical Hold Feature.
Wash 5 Thermal Cool-Down
Immediately after a heat step, a temperature-controlled
thermal cool-down may be programmed to prevent
fiber shock from sudden cool-down.
The “Heat” button is number 5.
Example: Heat up to 140°F with the time limit of
45 minutes.
Step XX Cycle XX
Wash
Step XX Cycle XX
0°F (or 0°C)
Step XX Cycle XX
Wash 5
Enter desired temperature for load to
cool down to. Three digits must be used
for temperature. If Fahrenheit, the valid
temperature range is 80° – 200°F. If
Celcius, valid temperature range is
25° – 90°C (example: 95°F).
Step XX Cycle XX
95°F
Step XX Cycle XX
0 hours
Step XX Cycle XX
1 hours 00 min
Thermal Cool-Down
is Wash 5.
Step XX Cycle XX
1 hours 05 min
Enter time in minutes
and press “Enter”
(example: 5 min).
Step XX Cycle XX
Heat
Step XX Cycle XX
0°F
Step XX Cycle XX
140°F
Step XX Cycle XX
0 hours 45 min
Step XX Cycle XX
0 hours