Programming
Topload Washer
Refer to Page 9 for Model Identification
TLW25C_SVG
Soil
Cycle
Temp
MEDIUM
Original Instructions
Keep These Instructions for Future Reference.
CAUTION: Read the instructions before using the machine.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 204370ENR1
January 2019

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ALLIANCE HWNNX2SP115CW01 and is the answer not in the manual?

ALLIANCE HWNNX2SP115CW01 Specifications

General IconGeneral
BrandALLIANCE
ModelHWNNX2SP115CW01
CategoryWasher
LanguageEnglish

Summary

Preliminary Information

About the Control

Details the advanced programmable computer and its features for controlling the washer.

Power Failure Recovery

Explains how the control saves cycle status during power failures and resumes operation.

Communications

Covers manual, infra-red, card reader, and network communication methods for programming.

Control Identification

Select Cycle Pads

Describes pads used to select specific washer cycles like NORMAL, PERM PRESS, and DELICATES.

Select Wash Temp Pads

Details pads for selecting water temperature (HOT, WARM, COLD) for the wash fill.

Select Cycle Modifier Pads

Explains the pad used to select cycle modifier options like LIGHT, MEDIUM, and HEAVY.

Display Identification

Light Emitting Diodes (LEDs)

Information on LEDs used to indicate chosen cycle and cycle status.

7-Segment Digits

Describes the use of 7-segment digits for time, vend price, and error messages.

Washer Operation

Start Mode

Details the mode when the vend price is satisfied or zero, indicating the cycle is ready.

Opening the Washer Lid

Explains the control's response when the washer lid is opened during various cycle stages.

Washer Operation

Changing Cycles

Instructions on how to change cycles and temperatures before the first fill.

Overflow Mode

Describes the control's behavior when an overflow level is detected in the washer.

Lockout Mode

Explains how to prevent machine use by specific users during programmed times.

Shutdown Mode

Details the mode entered based on Low Power/Auto-Shutdown options and programmed times.

Special Features

Programming Control

Allows owners to program cycle info, vend pricing, special vends, and run diagnostics.

Testing Machine and Control Functions

Enables owners to run specific diagnostic tests on washer operations.

Rapid Advance Feature

Allows quick advancement through an active cycle or into a cycle from Ready Mode.

Special Features

Special Vend

Allows programming programmable vend prices for specific hours and dates.

OPL Mode

Enables starting a cycle without satisfying the vend price.

Out of Order Mode

Allows owners to indicate the machine is not available for use.

Opening the Service Door

Coin Models

Manual programming for coin models, requiring service door and coin vault switch.

Card Reader Models

Manual programming for card reader models, involving unplugging a connector.

Entering the Manual Mode

How to Enter the Manual Mode

Step-by-step instructions on how to access Manual Mode for programming and testing.

Manual Mode Navigation

Overview of the five groups within Manual Mode: Programming, Audit, Reset, Rapid Advance, Diagnostics.

Programming Control

What Can Be Programmed

Details features programmable via keypad, including cycle info, vend pricing, and special vends.

Programmable Options Available

Lists and describes all available programming options for the control.

Programming Control

Power Fail Reset

Sets the duration the control stores active cycle info during a power failure.

Manual Rapid Advance

Enables or disables the rapid advance feature for quick cycle progression.

Manual Diagnostics

Enables or disables the manual diagnostics option for testing.

Factory Test

Enables or disables access to Factory Test mode for diagnostics.

Programming Control

Vend Price 1

Sets the vend price for NORMAL HOT cycles, to be set before other prices.

Vend Price 2

Sets the vend price for NORMAL WARM cycles.

Programming Control

Vend Price 9

Sets the vend price for DELICATES COLD cycles.

Vend Price Decimal Point

Enables a decimal point display for vend prices at two locations.

Programming Control

Coin 1 Value

Sets the numerical value for a coin entered in the first coin drop.

Coin 2 Value

Sets the numerical value for a coin entered in the second coin drop.

Start Pulse Value

Programs the value of the Start Pulse if used with aftermarket systems.

Programming Control

Default Cycle

Sets the default cycle that the machine enters in Ready Mode.

Audio Signal

Programs when signals may sound during washer operation.

Programming Control

Error Code Programming

Allows owners to turn on or off certain error codes in the control.

Programming Control

Set Real-Time Clock

Allows setting the control's internal clock to the correct time and date.

Set Daylight Savings Time

Allows setting the control's internal clock to daylight savings time and date.

Programming Control

How to Program Special Vend 1 Start Minute

Sets the minute for the start of Special Vend 1.

How to Program Special Vend 1 Start Month

Sets the month for the start of Special Vend 1.

Programming Control

How to Program Special Vend 1 Wash Status Agitate Steps Added Minutes

Adds time to agitate steps that have wash selected as their status.

How to Program Special Vend 1 Cycle Modifier Default Value

Sets the default cycle modifier (LIGHT, MEDIUM, HEAVY) upon entering Ready Mode.

Programming Control

Cycle Parameters

Allows setting time for various steps in each type of cycle.

Collecting Audit Information

How to Read Audit Data

Instructions on how to scroll through and read audit data options.

Manual Reset

How to Enter Manual Reset

Procedure to reset the washer control's programming to factory defaults.

Testing Machine and Electronic Control Functions

How to Enter Testing Feature

Steps to enter the testing mode to run diagnostic tests on washer operations.

How to Start Tests

Instructions on how to initiate a specific diagnostic test using the reference chart.

Testing Machine and Electronic Control Functions

Diagnostic Test Descriptions

Detailed descriptions of various diagnostic tests available for the washer.

Service Door Opening Test

Tests the service door switch status (open or closed).

Coin Vault Opening Test

Tests the coin vault switch status (open or closed).

Testing Machine and Electronic Control Functions

Water Purge Test

Tests the machine's water removal capabilities by energizing valves, spin, and pump.

Water Leak Detection Test

Checks for water leaks by monitoring water level changes during a cycle.

Testing Machine and Electronic Control Functions

Configuration 1 Display Test

Shows machine configuration values related to connected components.

Factory Test

To Enter Factory Test

Instructions on how to access Factory Test mode for machine diagnostics.

Error Codes

Rapid Advance Feature

How to Enter Rapid Advance

Steps to activate the Rapid Advance feature for quick cycle progression.

Clear Vend Feature

How to Clear Vend

Allows clearing the control when satisfying vend price and resetting to ready mode.

Power Fail Recovery

Communications Mode

Infra-red Communications

Allows control communication with external devices via infra-red.

Network Communications

Enables control communication with a network for programming and data reading.

Default Cycle Time