4. PRODUCT VIEW AND TECHNICAL CHARACTERISTICS
TABLE 2 - HYPER 400 technical characteristics
TECHNICAL CHARACTERISTICS U.M. HYPER 400
Recommended control board BIOS2 24 BIOS2 120 /
ECO
BIOS2 230 /
ECO
Supply voltage and frequency 24 Vdc 120Vac 60Hz 230Vac 50Hz
Motor absorption A 3 1 1
Motor power W 70 120 230
Capacitor μF -- 31,5 8
Motor speed rpm 1700 1750 1450
Average opening time (90°) sec. 17 17 20
Maximum gate size (Weight/Length) 100 kg / 3 m
133 kg / 2,5 m
200 kg / 1,5 m
150 kg / 3 m
183 kg / 2,5 m
250 kg / 1,5 m
200 kg / 3 m
233 kg / 2,5 m
300 kg / 1,5 m
Maximum thrust N 1600 2000 2000
Service % 70 50 50
Recommended daily cycles 100 100 100
Weight of the motor kg 6 7 7
Operating temperature °C -20°C ... +55°C
Degree of protection IP 44
Emergency release lever release with key
Internal mechanical stoppers optional
A. Motor body
B. Motor stem
C. Motor supply cable
D. Key to unlock
E. Release lever to unlock
F. Fixing point for rear bracket
G. Fixing point for front bracket
H. Screws for adjusting internal mechanical stoppers (op-
tional)
Description:
A
B
G
H
E
F
C
D