10
SR OPERATORS MANUAL
Flat lands with moderate speed and torque performance
expectations.
Contactors (Solenoids)
Stock 100 AMP
Use with 300A controllers.
Stock 70 AMP
Used with older ClubCars
vehicles
DO NOT Use with
Alltrax Controller
The solenoid is the primary disconnect of the
battery pack in the case of the an emergency. In
order to be effective, the solenoid needs to be
properly rated for the current that will be drawn
from the batteries. It is VERY important that the solenoid be rated
correctly. It is the only way to disconnect the batteries from the
motor/controller loop in case of a failure. Too small of a solenoid
increases the likelihood that the contacts will weld together and not
be able open.
UNACCEPTABLE
STANDARD DUTY