EasyManua.ls Logo

Alpine ZEN576S - Page 2

Alpine ZEN576S
2 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Assembling & Using Your Product
Unpack all components carefully. Please check to ensure all parts have been
removed from the packaging. Some splashing may occur.
Components:
A. Fountain
B. Submersible Pump
C. Back Cover
Assembling Instructions:
1. Place the fountain (A) base on a smooth and leveled surface.
2. Remove the pump (B) from its packaging and adjust the flow control to the
lowest setting to avoid splashing until the fountain (A) is completely assembled.
3. Then, connect the vinyl tubing from the opening on the back of the fountain (A)
and connect to the pump (B). After, place the pump (B) into the bottom of the
reservoir through the opening in the back of the fountain (A).
4. Attach the back cover (C) over the opening behind of the fountain.
5. Gently pour water into the fountain, being careful not to overflow and cause
splashing. Make sure the water completely submerges the pump so the water
runs clear during operation.
6. Plug the pump’s transformer into your local power supply. Make sure that there
is no water around the plugs and always keep the power source in a dry place.
o NOTE: We recommend that you use distilled water to prevent scale
build-up. The first time you operate the pump it can take up to 5
minutes for the air to be completely expelled and water begins to flow
properly.
Trouble Shooting & Caution
If you have any questions and/or problems, please contact the retail store you
purchased this fountain.
If your pump fails to run
Check the circuit breaker or try a different outlet to make sure the pump is
receiving electrical power.
Check the pump discharge and tubing for any kinks and/or obstructions
Any buildup obstructing the water flow can be flushed with a garden hose
Check the rotor by removing the front cover & plate to access the impellor area.
Turn the rotor and make sure that the rotor is not jammed or broken
If your pump “spews”
Check the water level to make sure the pump is completely submerged and
there if enough water in the basin to operate your fountain. Not having enough
water will cause your pump to spew
If your pump is making abnormal loud noises
Disconnect the pump from the electrical power supply and remove the front
cover & plate
Carefully grip the impeller and gently pull the impeller/rotor assembly out of the
pump housing
Rinse the impeller/rotor assembly and clean the cavity with clean water. If
breakage or damage is found, contact your local retailer for part
Fountain Care
We recommend to use Alpine’s all natural cleansing formula to eliminate foam,
lime scale and calcium buildup, fight mineral deposits, leave water crystal clear,
help prevent staining, remove organic contaminants and treat discolored water.
This formula will help prevent pump damage due to hard water build up.
i. For small sized fountains holding water up to 7liters of water, we
recommend Alpine Item # PPL100
ii. For larger sized fountains holding water over 7liters of water, we
recommend Alpine Item # PPL102
iii. For more information please visit www.alpine4u.com
Caution
o Always unplug the pump from the electrical outlet before
cleaning & handling
o Use with clean water only, do not place the fountain and/or
parts in any other liquid.
o Periodically change water & clean the pump to keep free
from micro-organisms
o Disconnect and store the unit in a dry place if not in use for
an extended period of time
o Do not operate with water above 90°F or 30°C
o Do not lift, carry, or pull the pump by the power cord
o Do not exceed the maximum voltage & wattage on
transformer
o NEVER LET THE PUMP RUN DRY

Related product manuals