Loading...
V E N T L E S S H O O D O P T I O N
#852 AR-7E Rotisserie Opera ti on & C ar e Ma nual 3 7
To ensure optimum performance
from the ventless hood, it is important
to establish and maintain a regular
c
leaning and maintenance schedule.
Use of the cleaning and maintenance
reminder form located in this manual is
highly recommended.
Access to the internal components, safety
switches, filters, etc., are gained by turning the single
fastener on the exterior top of the hood and opening
the door. A metal grease filter and charcoal filter are
located immediately inside the hood access door.
To help maintain the protective film coating on
polished stainless steel, clean the exterior of the
cabinet with a cleaner recommended for stainless steel
surfaces. Spray the cleaning agent on a clean cloth
and wipe with the grain of the stainless steel.
NOTE: Never use hydrochloric acid
(muriatic acid) on stainless steel.
CHARCOAL FILTER
The charcoal (odor and pollution control filter) is
located immediately inside the hood access door. The
charcoal filter should be inspected for contaminants
on a regular basis. Replacement must be made at a
minimum of three-month intervals more often if
heavy contaminants are visible or if the filter no
longer controls odors. To remove the filter, grasp on
both ends and pull out from either side of the hood.
WHEN REPLACING THE FILTER, MAKE CERTAIN
THE AIR FLOW ARROW POINTS LEFT
TOWARD THE HOOD FAN. MAKE CERTAIN THE
FILTER IS REPLACED IN THE FOUR-SIDED
METAL FRAME PROVIDED WITH THE HOOD.
GREASE FILTERS & METAL HOUSING (PLENUM)
The metal grease filter is located immediately
inside the hood. Cleaning frequency should be based
on oven usage. Grease-laden products such as red
meat, poultry, etc., require cleaning frequency of at
least once a week.
Remove the grease filter by pulling it straight out
of the housing from either side. Place the filter in the
dishwasher or wash separately by placing in hot,
soapy water until all grease and particles have been
removed. Rinse thoroughly. Allow the filter to air
dry before reinstalling.
Clean the interior metal
housing (plenum) with a
damp cloth and any good
commercial detergent or
grease solvent at the
recommended strength.
Avoid the use of abrasive
cleaning compounds,
chloride-based cleaners,
or cleaners containing
quaternary salts. Use a
degreasing agent if necessary.
GREASE FILTER
CHARCOAL FILTER
THE EDGES INSIDE THE HOOD HOUSING 
CAN BE SHARP. USE CAUTION WHEN 
REMOVING OR REPLACING FILTERS.
H O O D C L E A N I N G & M A I N T E N A N C E
GREASE