Weekly Maintenance
On a weekly basis, the heat exchanger on gas
models and convection elements on electric models
must be inspected.
Remove all wire shelves from inside the
appliance.
Remove le side rack from the oven cavity.
Flip the tabs or loosen the thumb screws on the
fan panel to the open position and swing the fan
guard cover plate toward the back of the oven.
Inspect the heat exchanger on gas models for
signs of grease and/or carbon buildup, scale
buildup, and any signs of major deformation.
Refer to images A and B.
Inspect that the  ue pipe seal is tight and intact.
Refer to image C.
Inspect the convection elements for signs of
cracking, grease and/or carbon buildup, scale
buildup, and any signs of major deformation.
Refer to image D.