Loading...
04.2018
www.alutech-group.com
Руководство
по монтажу и эксплуатации
Приводы Levigato (серия LG) для гаражных ворот
Русский
Керівництво
з монтажу та експлуатації
Приводи Levigato (серія LG) для гаражних воріт
Українська
Assembly and operation manual
Drives Levigato (LG series) for garage doors
English

Table of Contents

Questions and Answers

  • U
    ujacksonAug 17, 2025
    Why is my Alutech Garage Door Opener remote control not working or has a short range?
    • N
      nnorrisAug 17, 2025
      The remote control might not be working or have a short range because of a low battery. Check the remote-control battery and replace it if necessary.
  • K
    Kevin StokesAug 20, 2025
    What to do if my Alutech Garage Door Opener stops while opening and reverses when closing (error E1)?
    • C
      Cassandra ThomasAug 20, 2025
      This issue occurs when an obstacle is detected, causing excess force. Ensure there are no obstructions and verify the door operates smoothly without jamming. Also, check the balance of the door. If needed, increase the permissible force values using the ‘P5’–F1 and ‘P5’–F2 functions.
  • J
    Jonathan ParksAug 22, 2025
    How to fix an Alutech Garage Door Opener that doesn't work at all?
    • N
      Nancy LynchAug 23, 2025
      If the Alutech logo on the drive isn't lit and the display doesn't respond when pressing buttons, the issue is likely due to no supply voltage or a blown fuse. Check the supply voltage and inspect the fuse. If necessary, replace the fuse, ensuring the replacement matches the specified parameters.
  • Q
    qgarnerAug 25, 2025
    What does error E2 mean on my Alutech LG-800?
    • A
      Anita MurrayAug 26, 2025
      Error ‘E2’ indicates that the photocells are activated. Check the performance of photocells, replace, if necessary; check the selected photocells mode in the menu.
  • C
    christopher57Aug 27, 2025
    Why Alutech LG-800 doesn't start and shows error E5?
    • L
      Linda WhiteAug 27, 2025
      Error ‘E5’ indicates tripping based on the signal on input STOP. Check the working condition of the safety elements, connected to the STOP input (or crossover presence), replace them, if necessary.
  • D
    David RichardsonAug 30, 2025
    Why does my Alutech LG-800 Garage Door Opener reverse when closing and shows error E1?
    • B
      Bethany ByrdAug 30, 2025
      The error ‘E1’ during closing, causing a reverse movement, indicates that the optical sensors of the safety margin are activated. You should check the performance of the safety margin, and replace the failing components if needed. Also, check the selected safety margin mode in the menu.
  • G
    greenjenniferSep 1, 2025
    Why doesn't my Alutech Garage Door Opener react to photocells?
    • P
      Patrick BrownSep 1, 2025
      If the drive isn't reacting to obstacles on the optical axis of the photocells, it means that the photocells are malfunctioning or the incorrect operating mode of the photocells is selected. Check the performance of photocells, replace them if necessary, and check the selected photocells mode in the menu.
  • P
    Paul LewisSep 4, 2025
    What does error E4 mean on my Alutech Garage Door Opener?
    • D
      Denise McfarlandSep 4, 2025
      Error ‘E4’ indicates that an error occurred during the phototest. Check the performance of photocells, replace them if necessary, and check the selected photocells mode in the menu.
  • V
    Valerie CollinsSep 6, 2025
    What to do if my Alutech LG-800 Garage Door Opener shows error E6?
    • D
      drakedanielleSep 7, 2025
      Error ‘E6’ indicates that the drive overheats due to excessive heating or excessively intensive operation. Take a break in drive operation for 10 to 15 minutes to allow the internal elements to cool down. Avoid operating the drive with intensity exceeding the stated limits.
  • D
    Diane RodgersSep 9, 2025
    What does Alutech LG-800 Garage Door Opener error E8 mean?
    • R
      Robert LoganSep 9, 2025
      Error ‘E8’ during the setting of final positions indicates that either the support is not installed on the rail, or the support is installed at a larger distance from the OPEN position than required. Set the support at a distance of approximately 20 mm from the OPEN position and repeat the final positions adjustment procedure.

Summary

General Warnings and Safety Rules

Product Description

Delivery Scope

Lists all components included in the drive set and drive rail kit for garage doors.

Technical Specifications

Details technical parameters for LG series drives and rails, including forces, speed, power, and operating conditions.

Preparation for Assembly

Mounting

Drive Rail and Drive Mounting

Provides step-by-step instructions for installing the drive rail and mounting the drive unit onto the rail.

Manual Release

Explains how to release the drive carriage for manual door operation, with safety precautions.

Electrical Interfaces

Adjustment

Adjustment of the Door Position

Details manual and automatic methods for setting the open and closed end positions for the garage door.

Radio Control Setup

Guides through recording, configuring, and deleting remote controls for the drive system.

Deleting the Remote Control and Defining of the Record Number of the Remote

Explains how to delete specific remote controls or define their record numbers in the drive memory.

Deleting All Remote Controls

Provides steps to erase all previously programmed remote controls from the drive's memory.

Settings of Operation Values

Covers various operational settings like force, speed, acceleration, deceleration, and sensor modes.

Factory Reset

Describes how to restore the drive's settings to their default factory values.

Testing and Commissioning

Operation

Troubleshooting

Storage, Transportation and Disposal

Warranty Obligations

Commissioning Certificate

Information on Repairs During Warranty Period

Statement of Compliance

Alutech LG-800 Specifications

General IconGeneral
Max. force800 N
Warranty2 years
Supply voltage230 V
Motor TypeDC
Power Supply230 V, 50 Hz
ControlRemote control
Installation TypeCeiling mount