IPB-5000B
6. Description of Display Screens
6-17
(e) SCHEDULE#
Fixes the method of how to select a schedule.
EXT. (NP): Select a schedule by closing a schedule-selecting
terminal on Rear Panel
EXT. (P): Select a schedule by closing a schedule-selecting
terminal and a parity terminal on Rear Panel.
PANEL: Select a schedule on Front Panel.
Input a parity signal so that the total number of a closed schedule-selecting
terminal and a closed parity terminal may be odd.
(f) END SIG. TIME
Set the time period during which End signal or GOOD signal is output.
10/100ms: Outputs End signal for 10 ms or 100 ms.
HOLD: Outputs End or GOOD signal for the period during which
2ND STAGE terminal is closed. But if it is closed for 10
ms or less, the signals are output for 10 ms. If it is longer
than 10 ms, they are output for the closed period of 2ND
STAGE terminal.
(g) MONITOR MODE
Set the mode of a displayed monitor value.
EXCLUDE SLOPE: Slope period not included.
INCLUDE SLOPE: Slope period also included.
(h) CALCULATION MODE
Set the way of calculating a monitored value.
NORMAL: Set NORMAL usually.
FAST: If the takt time is needed to shorten, the shorter
calculation time is obtained when FAST is set.