Use the press machine in the following environment.
If used outside the operating environment in the table below, the machine and safety devices will
not function properly, causing a fire, failure, malfunction, or damage, which may lead to personal
injury.
Operating environment
Input power supply Voltage: 3-phase 200 V/ 220 V±10%
Frequency: 50 Hz/60 Hz±1 Hz
Grounding: ● TP, TPW, TPWL, PDL series
Class D (Class 3)
Inverter supporting item when an earth leakage
circuit breaker is used for inverter specification
machine
● SDE, SDEW, SWE Series
Independent grounding Class C (Special Class 3)
Inverter supporting item when an earth leakage
circuit breaker is used for inverter specification
machine (Recommended sensitivity current: 100 mA
or more)
Air supply: Supply pressure 0.5 MPa or more
(dry and clean compressed air without dust and drain)
Operating ambient temperature: +5 to +40ºC (no freezing)
Operating ambient humidity: 20 to 90% (no dew condensation)
Atmosphere: No salt and conductive dust
No corrosive gas or flammable gas
No splash of water, oil, chemicals, etc.
No affect by electrical noise
No direct sunlight and wind from air conditioner
Installation base: Tolerance: 70 kN/m
2
or more
The base dimensions differ depending on the model and
specifications of the machine. For details, refer to the separate
materials.
Caution when connecting external devices:
When connecting an external device, incorporate a protective circuit
such as a surge absorber or the like.
1. Operating environment and installation space of press machine
1-1. Operating environment
4