Page #1 background imageLoading...
Page #1 background image
© 2006 Goodman Company, L.P.
IO-297 6/06
AMH95
G
AS
-F
IRED
W
ARM
A
IR
F
URNACE
INSTALLATION I NSTRUCTIONS
*NOTE: Please contact your distributor or our
website for the applicable product data book
referred to in this manual.
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer. This includes all safety
precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety
warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than
when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer
in its safe use.
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety
practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is
a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.
(Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace)
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
Installer: Affix all manuals adjacent to the unit.
These furnaces comply with requirements
embodied in the American National Stan-
dard / National Standard of Canada ANSI
Z21.47·CSA-2.3 Gas Fired Central Fur-
naces.
C
US
®
®
is a trademark of Maytag Corporation and is used under
license to Goodman Company, L.P. All rights reserved.
www.amana-hac.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Amana AMH95 and is the answer not in the manual?

Amana AMH95 Specifications

General IconGeneral
TypeGas Furnace
Efficiency Rating95% AFUE
Stages of HeatingSingle-stage
WarrantyLimited Lifetime Heat Exchanger Warranty
Heating Capacity40, 000 - 120, 000 BTU/h
Blower MotorMulti-speed ECM

Summary

Attention Installing Personnel

I. Component Identification

II. Safety

Electrostatic Discharge (ESD) Precautions

Steps to prevent damage to electronic components from static discharge.

IV. Location Requirements & Considerations

V. Combustion & Ventilation Air Requirements

VII. Horizontal Applications & Considerations

IX. Vent/Flue Pipe & Combustion Air Pipe

Termination Locations

Details restrictions for vent and air intake pipe terminations.

X. Condensate Drain Lines & Drain Trap

XI. Electrical Connections

XII. Gas Supply and Piping

XIII. Circulating Air & Filters

XIV. Startup Procedure & Adjustment

XV. Normal Sequence of Operation

XVII. Safety Circuit Description

XVIII. Troubleshooting

Diagnostic Chart

Guidance for diagnosing and resolving common furnace operational issues.

XIX. Maintenance

Wiring Diagram