Verify all required components are present and intact.
Use caution when transporting or carrying the unit to avoid damage.
Read all instructions, understand procedures, gather tools before installation.
Ensure system components are manufacturer approved and AHRI listed; unmatched systems are not permitted.
Minimize tubing length, allow for coil removal for servicing without disconnecting.
Maintain required clearances for combustibility and service access.
Install secondary drain pan for units above living space; route drain to visible location.
Follow steps for installing the unit in an upflow configuration, including panel removal.
Follow steps for installing the unit in a downflow configuration, including panel removal.
Follow specifications for the condenser/heat pump for correct tubing size.
Ensure cut ends are round, burr-free, and clean to prevent refrigerant leaks.
Units with flowrator pistons may need piston changes for mix-matched applications.
Inspect supply voltage for single-phase, ensure agreement with unit nameplate.
Select wire size based on MCA, NEC/CSA standards, and voltage drop for proper operation.
Install NEC/CEC approved overcurrent device; size larger than MCA but not exceeding MOP.
Connect building supply to stripped black/red wires and ground screw in electrical compartment.
Use terminal block provided with HKS kit for power supply and air handler connections.
Install heater kit circuit breakers; use lugs for power supply connection.
Connect 24V control voltage to thermostat and condenser; use 18AWG wire up to 100ft.
Diagrams for ARUF air handlers, cooling units with heat kits, and two-stage heat.
Wiring diagram for cooling unit with optional 10KW and below heat kit.
Wiring diagram for cooling unit with optional 15KW and above heat kit.
Diagrams for ARUF air handlers, cooling units with heat kits, and two-stage heat.
Wiring diagram for cooling unit with optional 10KW and below heat kit.
Wiring diagram for cooling unit with optional 15KW and above heat kit.
Diagrams for ARUF heat pump units with optional heat kits (10kW & below, 15kW & above).
Wiring for cooling unit with optional heat kits (10kW and below).
Wiring for cooling unit with optional heat kits (15kW+) and two-stage heat.
Wiring for heat pump units with optional heat kits (10kW & below).
Wiring for heat pump units with optional heat kits (15kW & above).
Wiring diagram for the electronic blower time delay relay and its operating parameters.
Wiring diagram for ARUF**14** models, including high/low voltage connections.
Wiring diagram for ASPT**14** models, including high/low voltage connections.
Wiring diagram for the 3-phase heat kit installation.
Check and replace/clean air filters monthly for efficiency and to prevent damage.
Indoor and outdoor fan motors are permanently lubricated and require no oiling.
Safely flush aluminum coils with water; avoid corrosive chemical cleaners.