AVPTC**14**
© 2016-2017 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com - or - www.amana-hac.com
P/N: IOA-4021D Date: December 2017
AIR HANDLERS
INSTALLATION & OPERATING INSTRUCTIONS
®
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installa-
tion Manual. Observe all safety warnings. During installation or repair,
caution is to be observed. It is your responsibility to install the product
safely and to educate the customer on its safe use.
RECOGNIZE THIS SYMBOL AS A
SAFETY PRECAUTION.
Contents
1 Important Safety Instructions ............................................... 2
2 Shipping Inspection .............................................................. 3
3 Codes & Regulations ............................................................. 3
4 Replacement Parts ............................................................... 3
5 Pre-Installation Considerations ............................................. 3
6 Installation Location ............................................................. 3
7 Refrigerant Lines .................................................................. 5
8 Condensate Drain Lines......................................................... 8
9 Ductwork ............................................................................. 9
10 Return Air Filters .................................................................. 9
11 Electric Heat ......................................................................... 9
12 Electrical and Control Wiring ............................................... 10
13 Achieving 1.4% and
2.0% Airflow Low Leakage Rate ........................................ 11
14 24 Volt Wiring .................................................................... 11
15 Auxiliary Alarm Switch ........................................................ 12
16 AVPTC Motor Orientation ................................................... 12
17 Circulator Blower ............................................................... 13
18 Heat Kit Selection ............................................................... 16
19 Troubleshooting ................................................................. 16
20 ComfortNet™ System ........................................................ 17
21 Start-Up Procedure ............................................................ 19
23 Communications Troubleshooting Chart ............................. 20
24 Air Handler Advanced Features Menu ................................ 21
25 Troubleshooting ................................................................. 22
26 Diagnostic Codes ................................................................ 26
27 Wiring Diagrams ................................................................. 27
O
NLY
PERSONNEL
THAT
HAVE
BEEN
TRAINED
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
(
HEREINAFTER
, “
SERVICE
”)
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
SHOULD
SERVICE
THE
EQUIPMENT
. T
HE
MANUFACTURER
WILL
NOT
BE
RESPONSIBLE
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
ARISING
FROM
IMPROPER
SERVICE
OR
SERVICE
PROCEDURES
. I
F
YOU
SERVICE
THIS
UNIT
,
YOU
ASSUME
RESPONSIBILITY
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
WHICH
MAY
RESULT
. I
N
ADDITION
,
IN
JURISDICTIONS
THAT
REQUIRE
ONE
OR
MORE
LICENSES
TO
SERVICE
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
ONLY
LICENSED
PERSONNEL
SHOULD
SERVICE
THE
EQUIPMENT
. I
MPROPER
INSTALLATION
,
ADJUSTMENT
,
SERVICING
OR
REPAIR
OF
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
OR
ATTE MPTING
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
WITHOUT
PROPER
TRAINING
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.

Questions and Answers

  • B
    Brian DeckerAug 20, 2025
    Why is my Amana Air Handler not working?
    • J
      Joseph TurnerAug 20, 2025
      If your Amana Air Handler isn't working, check for any blockages in the filters, filter grills/registers, duct system, and the air handler's inlet/outlet. A sudden change in speed or torque, or a blockage of air inlet or outlet can cause this issue. Make sure to check filters, filter grills/registers, duct system and air handler inlet/outlet for blockages.
  • M
    michaelrivasAug 22, 2025
    What to do if my Amana Air Handler is not working?
    • D
      daniel03Aug 22, 2025
      If your Amana Air Handler is not working, it could be due to loose wiring at the circulator motor control leads. Make sure to tighten or correct the wiring connection. Additionally, the circulator blower motor or the integrated control module might have failed, so check and replace if necessary.
  • T
    Taylor WelchAug 23, 2025
    Why is my Amana Air Handler not turning on?
    • A
      Andrew WaltersAug 25, 2025
      If your Amana Air Handler is not working, it might be due to an incorrect circulator blower motor or an incorrect shared dataset in the integrated control module. Verify the circulator blower motor horsepower is the same as specified for your specific air handler model and replace if necessary. Also, verify the shared dataset is correct for your model and re-populate the data using the correct memory card if required.
  • L
    laura99Aug 26, 2025
    What to do if my Amana AVPTC49C14 are not getting power?
    • H
      Holly DaviesAug 26, 2025
      If your Amana Air Handler isn't operating, start by checking the power supply to ensure it's within the specified range on the rating plate. High or low AC line voltage or high ambient temperatures can cause this issue. Verify the line voltage is within the range specified on the rating plate.
  • L
    Lauren BurgessAug 28, 2025
    How to improve airflow in my Amana AVPTC49C14?
    • K
      Kelsey TaylorAug 28, 2025
      To address reduced performance or low airflow in your Amana Air Handler, start by inspecting the filters for any blockages and clean them or remove any obstructions. Also, check the ductwork for blockages, remove any obstructions, and ensure all registers are fully open. It may be that you have blocked filters or restrictive or undersized ductwork.
  • C
    cody52Aug 29, 2025
    What causes my Amana Air Handler to not operate?
    • W
      William StantonAug 29, 2025
      If your Amana Air Handler isn't operating, it might be due to loose or disconnected wiring at the circulator motor power leads. Ensure to tighten or correct the wiring connection. Also, for 3/4 Hp and 1 Hp models, verify a continuous circuit through the inductor and replace it if there is an open or short circuit. Check circulator blower motor.
  • J
    Jennifer ThomasAug 31, 2025
    How to fix an Amana Air Handler that is not working?
    • B
      Brian WellsSep 1, 2025
      If your Amana Air Handler isn't operating, check the circulator blower for any obstructions. Additionally, seized circulator blower motor bearings or a failed circulator blower motor could be the cause. Remove and repair/replace wheel/motor if necessary. Also check circulator blower motor shaft rotation and motor, replace motor if necessary.
  • K
    Katelyn AndradeSep 2, 2025
    How do I troubleshoot my Amana Air Handlers?
    • M
      Mike RhodesSep 3, 2025
      If your Amana Air Handler is not operating, there may be a short in the low voltage wiring. Locate and correct the short in the low voltage wiring. If that's not the case, replace the fuse with a 3-amp automotive type.
  • D
    Dawn SanchezSep 5, 2025
    Why is my Amana Air Handler operating at reduced performance?
    • S
      Sara SheltonSep 5, 2025
      If your Amana Air Handler operates at reduced performance or operates on low stage when high stage is expected, start by checking the filters for blockage, clean the filters, or remove any obstruction. Also, check the ductwork for blockage, remove any obstruction, and verify all registers are fully open. Make sure to verify ductwork is appropriately sized for system, resize/replace ductwork if necessary.
  • M
    Melissa LeonardSep 7, 2025
    Why is my Amana AVPTC49C14 Air Handlers outdoor unit not working?
    • J
      Jennifer BeasleySep 7, 2025
      If the outdoor unit of your Amana system isn't operating, the issue might be improper low voltage wiring between the indoor and outdoor units. Locate and correct any improper low voltage wiring issues. Alternatively, the outdoor control board might have lost power during operation, so identify the reason for this power loss.

Summary

Important Safety Instructions

Safety Warnings and Precautions

General Safety Advisories

Highlights general warnings related to electrical shock, property damage, and personal injury.

Carbon Monoxide Hazard

Details the risks of carbon monoxide poisoning and necessary ventilation precautions.

Pre-Installation Considerations

Refrigerant Line Installation

Thermal Expansion Valve Adjustment

Condensate Drain Line Installation

Electric Heat Kit Installation

Electrical and Control Wiring

Wire Sizing and Ampacity

Guidelines for selecting appropriate wire size based on ampacity and voltage drop.

Maximum Overcurrent Protection

Requirements for overcurrent protection devices like fuses or circuit breakers.

Supply Voltage Electrical Connections

Instructions for connecting the main power supply conductors to the unit.

Achieving Airflow Leakage Standards

24 Volt Thermostat Wiring

Circulator Blower Operation

Troubleshooting Overview

Electrostatic Discharge Precautions

Steps to prevent damage to electronic components from static electricity.

Diagnostic Codes and Indicators

Using the LED display and diagnostic chart to identify operational issues.

Fault Recall Procedure

ComfortNet System Overview

System Communication and Operation

Explains the digital communication between ComfortNet system components.

Control Wiring for ComfortNet

ComfortNet Diagnostics

Network Troubleshooting

System Troubleshooting Guide

Start-Up Procedure Checklist

Regular Maintenance Recommendations

Communications Troubleshooting Chart

Advanced Features Menu

Troubleshooting Common Faults

Abnormal Operation Symptoms and Fault Codes

Details symptoms of abnormal operation and associated LED indicators and fault codes.

Troubleshooting Common Faults - Sheet 2

Troubleshooting Common Faults - Sheet 3

Troubleshooting Common Faults - Sheet 4

Diagnostic Codes Reference

Wiring Diagrams

Homeowner Maintenance Recommendations

Amana AVPTC49C14 Specifications

General IconGeneral
BrandAmana
ModelAVPTC49C14
CategoryAir Handlers
LanguageEnglish