AVPTC**14**
© 2016-2017 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com - or - www.amana-hac.com
P/N: IOA-4021D Date: December 2017
AIR HANDLERS
INSTALLATION & OPERATING INSTRUCTIONS
®
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installa-
tion Manual. Observe all safety warnings. During installation or repair,
caution is to be observed. It is your responsibility to install the product
safely and to educate the customer on its safe use.
RECOGNIZE THIS SYMBOL AS A
SAFETY PRECAUTION.
Contents
1 Important Safety Instructions ............................................... 2
2 Shipping Inspection .............................................................. 3
3 Codes & Regulations ............................................................. 3
4 Replacement Parts ............................................................... 3
5 Pre-Installation Considerations ............................................. 3
6 Installation Location ............................................................. 3
7 Refrigerant Lines .................................................................. 5
8 Condensate Drain Lines......................................................... 8
9 Ductwork ............................................................................. 9
10 Return Air Filters .................................................................. 9
11 Electric Heat ......................................................................... 9
12 Electrical and Control Wiring ............................................... 10
13 Achieving 1.4% and
2.0% Airflow Low Leakage Rate ........................................ 11
14 24 Volt Wiring .................................................................... 11
15 Auxiliary Alarm Switch ........................................................ 12
16 AVPTC Motor Orientation ................................................... 12
17 Circulator Blower ............................................................... 13
18 Heat Kit Selection ............................................................... 16
19 Troubleshooting ................................................................. 16
20 ComfortNet™ System ........................................................ 17
21 Start-Up Procedure ............................................................ 19
23 Communications Troubleshooting Chart ............................. 20
24 Air Handler Advanced Features Menu ................................ 21
25 Troubleshooting ................................................................. 22
26 Diagnostic Codes ................................................................ 26
27 Wiring Diagrams ................................................................. 27
O
NLY
PERSONNEL
THAT
HAVE
BEEN
TRAINED
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
(
HEREINAFTER
, “
SERVICE
”)
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
SHOULD
SERVICE
THE
EQUIPMENT
. T
HE
MANUFACTURER
WILL
NOT
BE
RESPONSIBLE
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
ARISING
FROM
IMPROPER
SERVICE
OR
SERVICE
PROCEDURES
. I
F
YOU
SERVICE
THIS
UNIT
,
YOU
ASSUME
RESPONSIBILITY
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
WHICH
MAY
RESULT
. I
N
ADDITION
,
IN
JURISDICTIONS
THAT
REQUIRE
ONE
OR
MORE
LICENSES
TO
SERVICE
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
ONLY
LICENSED
PERSONNEL
SHOULD
SERVICE
THE
EQUIPMENT
. I
MPROPER
INSTALLATION
,
ADJUSTMENT
,
SERVICING
OR
REPAIR
OF
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
OR
ATTE MPTING
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
WITHOUT
PROPER
TRAINING
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.

Questions and Answers

  • T
    tonyaporterAug 19, 2025
    Why is my Amana Air Handler not working?
    • D
      David KaiserAug 20, 2025
      If your Amana Air Handler isn't working, check for any blockages in the filters, filter grills/registers, duct system, and the air handler's inlet/outlet. A sudden change in speed or torque, or a blockage of air inlet or outlet can cause this issue. Make sure to check filters, filter grills/registers, duct system and air handler inlet/outlet for blockages.
  • K
    Kim RamirezAug 21, 2025
    What to do if my Amana Air Handler is not working?
    • S
      Samantha MorseAug 22, 2025
      If your Amana Air Handler is not working, it could be due to loose wiring at the circulator motor control leads. Make sure to tighten or correct the wiring connection. Additionally, the circulator blower motor or the integrated control module might have failed, so check and replace if necessary.
  • M
    Mark SharpAug 25, 2025
    Why is my Amana Air Handler not turning on?
    • J
      Joanna BishopAug 25, 2025
      If your Amana Air Handler is not working, it might be due to an incorrect circulator blower motor or an incorrect shared dataset in the integrated control module. Verify the circulator blower motor horsepower is the same as specified for your specific air handler model and replace if necessary. Also, verify the shared dataset is correct for your model and re-populate the data using the correct memory card if required.
  • T
    Taylor RomanAug 26, 2025
    What to do if my Amana AVPTC25B14 are not getting power?
    • J
      jesse47Aug 26, 2025
      If your Amana Air Handler isn't operating, start by checking the power supply to ensure it's within the specified range on the rating plate. High or low AC line voltage or high ambient temperatures can cause this issue. Verify the line voltage is within the range specified on the rating plate.
  • D
    Debbie PowersAug 27, 2025
    How to improve airflow in my Amana AVPTC25B14 Air Handlers?
    • S
      Stephanie BrownAug 28, 2025
      To address reduced performance or low airflow in your Amana Air Handler, start by inspecting the filters for any blockages and clean them or remove any obstructions. Also, check the ductwork for blockages, remove any obstructions, and ensure all registers are fully open. It may be that you have blocked filters or restrictive or undersized ductwork.
  • R
    Rachel LopezAug 30, 2025
    What causes my Amana Air Handler to not operate?
    • S
      Stephanie BauerAug 30, 2025
      If your Amana Air Handler isn't operating, it might be due to loose or disconnected wiring at the circulator motor power leads. Ensure to tighten or correct the wiring connection. Also, for 3/4 Hp and 1 Hp models, verify a continuous circuit through the inductor and replace it if there is an open or short circuit. Check circulator blower motor.
  • M
    Michael CochranAug 31, 2025
    How to fix an Amana Air Handler that is not working?
    • C
      clarkjonathanSep 1, 2025
      If your Amana Air Handler isn't operating, check the circulator blower for any obstructions. Additionally, seized circulator blower motor bearings or a failed circulator blower motor could be the cause. Remove and repair/replace wheel/motor if necessary. Also check circulator blower motor shaft rotation and motor, replace motor if necessary.
  • M
    Monique JonesSep 2, 2025
    How do I troubleshoot my Amana Air Handlers?
    • D
      Deborah WilsonSep 2, 2025
      If your Amana Air Handler is not operating, there may be a short in the low voltage wiring. Locate and correct the short in the low voltage wiring. If that's not the case, replace the fuse with a 3-amp automotive type.
  • J
    Jessica AllenSep 5, 2025
    Why is my Amana Air Handler operating at reduced performance?
    • D
      dominguezdanielSep 5, 2025
      If your Amana Air Handler operates at reduced performance or operates on low stage when high stage is expected, start by checking the filters for blockage, clean the filters, or remove any obstruction. Also, check the ductwork for blockage, remove any obstruction, and verify all registers are fully open. Make sure to verify ductwork is appropriately sized for system, resize/replace ductwork if necessary.
  • J
    John WiseSep 6, 2025
    Why is my Amana Air Handlers outdoor unit not working?
    • E
      Erik AdamsSep 6, 2025
      If the outdoor unit of your Amana system isn't operating, the issue might be improper low voltage wiring between the indoor and outdoor units. Locate and correct any improper low voltage wiring issues. Alternatively, the outdoor control board might have lost power during operation, so identify the reason for this power loss.

Summary

Safety and Installation Precautions

Installer and Service Personnel Responsibilities

Emphasizes installer familiarity with the manual and the need for trained service personnel.

Critical Safety Warnings

Electrical and Environmental Hazards

Covers warnings on flammable materials, electrical shock, high voltage, and carbon monoxide.

Protective Gear and Grounding

Recommends safety gear and stresses the importance of proper electrical grounding.

Installation Preparation and Compliance

Pre-Installation Considerations

Preparation, system matches, clearances, and horizontal application requirements.

Installation Location and Orientation

Upflow, Horizontal Left, and Downflow Installation

Details for various installation orientations, including drain setup and kits.

Refrigerant Line Installation

Tubing Size, Preparation, and Brazing

Guidelines for selecting, preparing, and brazing refrigerant lines with safety precautions.

Refrigerant System Adjustment

TXV Tubing Connections

Steps for connecting refrigerant lines to TXV models.

Thermal Expansion Valve System Adjustment

Process for adjusting the TXV to achieve proper subcooling and superheat.

Condensate Drain Line Management

Drain Line Installation and Traps

Procedures for installing drain lines, including pitch, insulation, and traps.

Electrical Wiring and Connections

Power Supply and Wire Sizing

Inspect power supply voltage and select correct wire sizes.

Heat Kit, Low Voltage, and Airflow Settings

Circulator Blower Operation and Speed Control

Blower Speed and Airflow DIP Switch Settings

Heat Kit Selection and Troubleshooting Basics

Heat Kit Selection and ESD Precautions

Guidance on selecting heat kits and preventing ESD damage.

System Faults and ComfortNet Overview

ComfortNet System Controls and Diagnostics

Start-Up Procedures and Maintenance

Pre-Start-Up Checklist and Warnings

Checklist for starting the unit and high voltage warnings.

Communications Troubleshooting

Communications Troubleshooting Chart

Detailed chart for diagnosing communication failures using LEDs and error codes.

Air Handler Advanced Features Menu

Troubleshooting Common Fault Codes (Part 1)

Troubleshooting Common Fault Codes (Part 2)

Troubleshooting Motor Faults (Part 1)

Troubleshooting Motor Faults (Part 2)

Diagnostic Code Reference

7-Segment LED Diagnostic Code Table

Comprehensive table of diagnostic codes and their meanings for troubleshooting.

Wiring Diagrams and Color Codes

High Voltage Warning and Control Module Wiring

Warning for high voltage during wiring work and the control module's wiring diagram.

3-Phase Heat Kit Wiring Diagram

Amana AVPTC25B14 Specifications

General IconGeneral
ModelAVPTC25B14
TypeAir Handler
Heating Capacity25, 000 BTU/H
AirflowUp to 800 CFM
RefrigerantR-410A
Voltage208/230V
Phase1
Motor TypePSC
Depth21 inches
Cabinet TypeMetal