What to do if my Amana Air Handler has high water level?
- BBarbara HendersonSep 9, 2025
If your Amana Air Handler isn't operating, the high water level in the evaporation coil could be the cause. Check the evaporator drain pan, trap, and piping.
What to do if my Amana Air Handler has high water level?
If your Amana Air Handler isn't operating, the high water level in the evaporation coil could be the cause. Check the evaporator drain pan, trap, and piping.
What to do if Amana Air Handler has no network data?
If your Amana Air Handler isn't operating and there's no network data, populate the shared data set using a memory card.
What if my Amana Air Handler blower doesn't contain an appropriate shared data set?
If your Amana Air Handler isn't operating, and the blower does not contain an appropriate shared data set, populate the correct shared data using a memory card.
What to do if Amana Air Handler operation is different than expected?
If your Amana Air Handler's operation is different than expected, or if it's not operating at all, it could be that the shared data set on the memory card has been rejected by the integrated control module. Verify the shared data set is correct for the specific model. Re-populate the data using the correct memory card if required.
What if my Amana Air Handler has error with integrated control module shared data?
If your Amana Air Handler isn't operating, it could be due to an error with the integrated control module shared data. Verify that the control is populated with the correct shared data.
| Model | AVPTC25B14 |
|---|---|
| Type | Air Handler |
| Heating Capacity | 25, 000 BTU/H |
| Airflow | Up to 800 CFM |
| Refrigerant | R-410A |
| Voltage | 208/230V |
| Phase | 1 |
| Motor Type | PSC |
| Depth | 21 inches |
| Cabinet Type | Metal |
Emphasizes installer familiarity with the manual and the need for trained service personnel.
Covers warnings on flammable materials, electrical shock, high voltage, and carbon monoxide.
Recommends safety gear and stresses the importance of proper electrical grounding.
Preparation, system matches, clearances, and horizontal application requirements.
Details for various installation orientations, including drain setup and kits.
Guidelines for selecting, preparing, and brazing refrigerant lines with safety precautions.
Steps for connecting refrigerant lines to TXV models.
Process for adjusting the TXV to achieve proper subcooling and superheat.
Procedures for installing drain lines, including pitch, insulation, and traps.
Inspect power supply voltage and select correct wire sizes.
Guidance on selecting heat kits and preventing ESD damage.
Checklist for starting the unit and high voltage warnings.
Detailed chart for diagnosing communication failures using LEDs and error codes.
Comprehensive table of diagnostic codes and their meanings for troubleshooting.
Warning for high voltage during wiring work and the control module's wiring diagram.
Loading...