RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installation Manual.
Observe all safety warnings. During installation or repair, caution is to be observed.
It is your responsibility to install the product safely and to educate the customer on its safe use.
ARUF**14** / ASPT**14**
1 Important Safety Instructions
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards.
It is the owner’s and installer’s responsibility to read and
comply with all safety information and instructions accom-
panying these symbols. Failure to heed safety information
increases the risk of personal injury, property damage, and/
or product damage.
AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS
IO-901
2/2015
Keep this literature in a safe place for future reference.
1 Important Safety Instructions...................................1
2 Shipping Inspection ............................................... 3
2.1 Parts .......................................................... 3
2.2 Handling ...................................................... 3
3 Codes & Regulations ..............................................3
4 Replacement Parts ................................................3
5 Pre-Installation Considerations ................................ 3
5.1 Preparation .................................................. 3
5.2 System Matches ............................................. 3
5.3 Interconnecting Tubing..................................... 3
5.4 Clearances ................................................... 4
5.5 Horizontal Applications .................................... 4
6 Installation Location .............................................4
6.1 Upflow Installation ......................................... 4
6.2 Horizontal Left Installation ............................... 4
6.3 Downflow..................................................... 4
6.4 Horizontal Right Installation.............................. 5
7 Refrigerant Lines .................................................. 7
7.1 Tubing Size ................................................... 7
7.2 Tubing Preparation ......................................... 7
7.3 Special Instructions......................................... 7
7.4 Tubing Connections for Flowrator Model ............... 7
7.5 Tubing Connections for TXV Models ...................... 8
8 Condensate Drain Lines .......................................... 8
9 Ductwork............................................................ 9
9.1 Return Ductwork ............................................ 9
10 Return Air Filters ................................................9
11 Electric Heat......................................................9
12 Electrical and Control Wiring ............................... 11
12.1 Building Electrical Service Inspection................ 11
12.2 Wire Sizing ............................................... 11
12.3 Maximum Overcurrent Protection (MOP) ............ 11
12.4 Electrical Connections – Supply Voltage ............. 12
12.4.1 Air Handler Only (Non-Heat Kit Models) ..... 12
12.4.2 Air Handler - Non-Circuit Breaker Heat Kits......12
12.4.3 Air Handler With Circuit Breaker Heat Kit........ 12
12.5 Low Voltage Connections............................... 12
12.5.1 Thermostats .......................................... 12
12.6 Speed Tap Adjustment .................................. 12
13 Achieving 1.4% Low Leakage Rate ......................... 13
14 Start-Up Procedure............................................ 13
15 Regular Maintenance.......................................... 13
16 Airflow Data .................................................... 14
21 Wiring Diagrams................................................ 20
Contents
Question and Answer IconNeed help?

Do you have a question about the Amana ARUF37D14 Series and is the answer not in the manual?

Summary

Safety Instructions and General Precautions

General Safety Precautions

Highlights general safety precautions, including the importance of reading instructions and caution during installation/repair.

High Voltage and Grounding Safety

Critical warnings about high voltage, emphasizing power disconnection and the necessity of an uninterrupted electrical ground.

Carbon Monoxide Poisoning Hazard

Warns about carbon monoxide poisoning risks in enclosed areas and the need for adequate ventilation.

Electrical Wiring and Components

Low Voltage Wiring and Speed Control

Supply Voltage and Low Voltage Connections

Details supply voltage connections and low voltage wiring for thermostats and outdoor units.

Wiring Diagrams and Control Components

Low Voltage Wiring Configurations

Details wiring configurations for cooling, heat pump, and electric heating applications with thermostats.

Specific Wiring Scenarios

Cooling Unit with Heat Kits Wiring

Wiring diagrams for cooling units with optional heat kits (10kW and below, 15kW and above).

Heat Pump Unit Wiring Diagrams

Wiring diagrams for heat pump units with optional heat kits and outdoor thermostats.

3-Phase Heat Kit Installation

3-Phase Heat Kit Wiring and Setup

Instructions for installing a 3-phase heat kit, ensuring speed tap compatibility and marking the serial plate.

Amana ARUF37D14 Series Specifications

General IconGeneral
ModelARUF37D14 Series
TypeAir Handler
RefrigerantR-410A
Cabinet MaterialGalvanized Steel
Phase1
Motor TypePSC
Cooling Capacity (BTU)37, 000
Cooling Capacity (tons)3.0
Airflow (CFM)1200
Voltage208/230V
Filter TypeDisposable