Basic Operation
1. Battery and Surge Protected Outlets
The unit has several battery and surge protected outlets (4 for 600VA and 6 for 800VA unit)
to ensure temporary uninterrupted operation of your equipment during a power failure. (Do
not plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or
other large electrical device into the “Battery and Surge Protected Outlets.” The power
demands of these devices will overload and possibly damage the unit.).
2. Full-Time Surge Protection Outlets
The unit has several surge suppression outlets (4 for 600VA and 6 for 800VA unit) to provide
surge and line noise protection.
3. Power Switch
To turn the UPS on, press the power button for approximately 2 seconds - you will hear a
constant tone (1 second) - and release after a short beep.
To turn the UPS off, press the power button for approximately 2 seconds - you will hear a
constant tone (1 second) - and release after two short beeps.
Quickly press the POWER button twice can turn off or turn on the audible Alarm. The default
setting is for the Alarm On.
To turn the alarm off, press the power button twice. You will hear two short beeps when the
alarm is turned off.
To turn the alarm back on, press the power button twice. You will hear a short beep when the
alarm is turned on.
*When the alarm is turned off, no audible notification when the UPS reaches a (low)
battery state.
4. Power On Indicator (green)
This LED is illuminated when the utility power is normal and the UPS outlets are providing
power, free of surges and spikes. When In the event of a complete power loss, severe
brownout, or over-voltage, the UPS will turn to battery mode and the LED will flash.
Please refer to the following “Definitions for Illumination LED Indicators” for more information.
5. Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault
protection.
6. USB Port to PC
The USB port allows connection and communication between the USB port on the personal
computer and the UPS unit. The UPS communicates its status to the Power Management
Software.
7. Outlets Designed for AC Adapters
The UPS unit has several widely-spaced outlets (2 for 600VA and 4 for 800VA unit), so AC
power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets.