8
Denitions For Illuminated LED Indicators
Power ON Alarm
CONDITION
On Off Normal
Flash when
Beeps
Beeps twice every
30 seconds
Utility Failure - Battery Mode
The UPS is providing power to battery and surge
protected outlets from its battery.
Flash when
Beeps
Rapid Beeping
every 1/2 second
Utility Failure - Low Battery
The UPS is providing battery power. Rapid beeping
indicates the unit will run out of power shortly.
On Constant tone
Overload - Occurs when connected equipment
exceeds the listed capacity of the UPS. Turn the
UPS off, unplug at least one piece of equipment from
battery outlets, reset the circuit breaker and turn the
unit on.
Off Constant tone
Charge Fault - In line mode, the battery charging
voltage is too high or too low.
Off Constant tone
Utility Failure - The frequency is beyond 47-63 Hz.
The UPS will not turn on in line mode.
Technical Specications
Model Standby UPS 600VA Standby UPS 800VA
Capacity 600 VA / 360 W 800 VA / 450 W
Input Voltage on Utility 96V typical - 140V typical
Input Frequency 50/60 ± 3 Hz (Auto-sensing)
Nominal Input Voltage 120 VAC
On-Battery Output Voltage 120 VAC ± 8 %
On-Battery Output Frequency 50 Hz / 60 Hz ± 1 %
Transfer Time 8 ms Typical
Max. Load for UPS Outlets 600 VA / 360 W 800 VA/450 W