3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).
Make sure the wall branch outlet is protected by a fuse or circuit
breaker and does not service equipment with large electrical demands
(e.g. air conditioner, refrigerator, copier, etc.). The warranty prohibits the
use of extension cords, outlet strips, and surge strips in conjunction
with the UPS.
4. Press the power switch to turn the unit on. The Power On indicator will illuminate green and the
unit will “beep” twice.
5. If an overload is detected, an audible alarm will be sounded and the unit will emit long beep.
To correct this, turn the UPS off and unplug at least one piece of equipment from the battery
power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period of time, cover it and store with the battery fully
charged. While in storage, recharge the battery every three months to ensure battery life.
8. For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be
easily accessible.
9. Do not lay the UPS on its side and please follow the direction as below to mount the UPS to
ensure the battery life.
600VA
800VA
600VA 800VA