Cleaning, maintenance and repair
Pantera 4503 CP2_E3A_E5 BAG0196.2 06.19
14.10.1 Calibrate the flow meter
• Calibrate the flow meter at least once a year.
•
Calibrate the flow meter:
after removing the flow meter.
After long periods of operation, because spray residue
deposits can form in the flow meter.
If differences occur between the required spray rate
and the actual spray rate.
Note the displayed "Impulse" value when you drive the field
sprayer away from your location for determining the amount
of water applied. The impulse value displayed lapses when
transporting the field sprayer.
Compare the flow meter with the flow meter at least once a
year.
Calibrate the flow meter with the return flow meter at the
following times:
after calibrating the flow meter.
After removing the return flow meter.
Move-out in work menu "Sprayer". The comparison
be carried out when no fluid is used via the boom.
Pay attention to the operating instructions for the control termi-
nal; Chapter Pulses per litre.