RADIANT Straight
INSTALLATION INSTRUCTIONS
Please read the following information before installing and using your Heated Towel Rack.
WARNINGS
- These units should be installed by a certified electrician in accordance with the National Electrical Code (NEC) and the Canadian Electrical Code (CEC).
- The unit requires a 120 volt, 60Hz power source and should be installed on a GFCI protected circuit.
- Plug-in units should be connected to a grounded outlet with a minimum rating of 10 amps.
- Follow installation instructions to ensure unit is securely fixed to wall. Unit is designed for drying towels. Under no circumstances should anybody climb on or hang on unit.
- Unit is intended for indoor use only. Do not place units inside a shower, sauna, steam room, or wherever unit would be exposed to water.
CAUTION
- As this is a heating device, the surface temperature can increase depending on the ambient temperature in the room and the number of towels applied to the unit.
- Overloading the unit will cause the unit to become extremely hot and may result in a burn if touched and/or damage to towels.
- The fasteners provided with the installation kit are for convenience only and are not suitable for all installation conditions.
- It is the ultimate responsibility of the installer to ensure proper mounting hardware is employed in attaching the unit to the wall.
OPERATING INSTRUCTION
- After installation, connect the electric power.
- Remove the protective cover from the switch and turn it to the on position.
- The indicator light will glow red and the towel warmer will start to heat — Allow 10-20 minutes to heat up.
- This towel warmer has been designed to run continuously — Turn off the switch or unplug the cord when the towel warmer is not in use for long periods of time.
- Never use an extension cord for Plug-in models.
- The Radiant Collection features an
Integrated on/off switch.
- Remove plastic cover after installation.
- Switch is located on the bottom of the
left vertical bar.
- Press switch to power on unit.
- Switch will illuminate when on.
CARE & MAINTENANCE
- Towels which contain soap or detergent residue may appear to have scorch marks; this is simply discoloration of the residue in the towels themselves.
- The unit is constructed from extremely durable 304 stainless steel. To maintain a good appearance, follow these simple instructions:
- For routine cleaning, simply switch off the unit, allow to cool to room temperature, wipe with a damp cloth and buff with a soft, dry cloth.
- Under no circumstances should abrasive cleaners be used to clean the unit.
CONTACT
TEL:
4043509738
FAX:
4043550166
EMAIL:
customerservice@ambaproducts.com
WEB:
www.ambaproducts.com
INCLUDED COMPONENTS TOOLS REQUIRED
ELECTRICAL INFO
Two year limited warranty
with proof of purchase will
apply if all Terms and
Conditions of Sale are met
and Installation Instructions
are adhered to.
WARRANTY
PLUG-IN MODELS INTEGRATED SWITCH
REQUIRES
GROUNDED
OUTLET
AVAILABLE MODELS
RWH-SP
RWP-SP
RWH-SB
RWP-SB
WH - wall mounted & hardwired
WP - wall mounted & plug-in
Page 1
SWITCH
SWITCH
COVER
P-Polished B-Brushed
! CAUTION — SURFACE OF UNIT IS HOT WHEN ON !
www.ambaproducts.com/warranty
FOR FULL WARRANTY VISIT:
150
watts
1.3
amps
120
volts
4x
DB
4x
G
4x
H
1x
4x
E
M8x65ST4.2*40
A
4x
C
4x
4x
F
M6x10
I
2x
#6-32 x 3/4 -in
Question and Answer IconNeed help?

Do you have a question about the Amba RADIANT Straight and is the answer not in the manual?

Amba RADIANT Straight Specifications

General IconGeneral
BrandAmba
ModelRADIANT Straight
CategoryFood Warmer
LanguageEnglish

Summary

Safety Warnings and Precautions

General Warnings

Units must be installed by a certified electrician, use a GFCI circuit, and are for indoor use only.

Cautionary Notes

Device surface temperature can increase; overloading causes overheating and potential damage.

Product Operation and Care

Operating Instructions

Instructions for turning the unit on/off and heating up. Designed for continuous use.

Care and Maintenance

Cleaning instructions using a damp cloth and buffing. Avoid abrasive cleaners.

Installation Components and Specifications

Included Components

List of parts included for installation, such as screws and mounting hardware.

Tools Required

List of tools necessary for installation, primarily for hardwired models.

Electrical Information

Specifications including wattage, amperage, and voltage for the unit.

Product Variants and Support

Available Models

Overview of different models like RWH-SP, RWP-SP, RWH-SB, RWP-SB with finish options.

Plug-in vs. Integrated Switch

Describes plug-in models requiring a grounded outlet and integrated switch features.

Warranty Information

Details a two-year limited warranty with proof of purchase and adherence to terms.

Contact Information

Provides contact details via phone, fax, email, and website for customer service.

Assembly Steps

Step 1: Mounting Preparation

Illustrates marking wall positions and attaching mounting hardware with specified dimensions.

Step 2: Attaching the Rack

Shows how to connect the towel rack to the previously installed wall mounts.

Step 3: Securing the Unit

Details securing the rack to the wall brackets, with a caution against over-tightening.

Step 4: Finalizing Installation

Illustrates turning the unit on with the integrated switch after installation.

Related product manuals