6000E ELECTRONICALLY CONTROLLED PRECISION LUBRICATION SYSTEM
Operator’s Manual
P A G E | 10
Too Much Liquid
T60A adjustment screw is too far open: adjust clockwise.
Not Enough Liquid
Too far closed: adjust counterclockwise
Liquid outlet (or hose) is kinked: replace.
Liquid Volume is Inconsistent
Injector is contaminated: clean.
O-ring seal is faulty: replace or rebuild.
Liquid Volume is Increasing with Time
O-ring on adjustment stem is deteriorated: replace.
Liquid Leaking from Pump Body
O-ring seals are worn: replace.
Piston sleeve is not tight: tighten.
Piston sleeve is worn: rebuild complete injector