EasyManua.ls Logo

AMCOL 6000E - T60 A Posi-pump Troubleshooting

AMCOL 6000E
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6000E ELECTRONICALLY CONTROLLED PRECISION LUBRICATION SYSTEM
Operator’s Manual
P A G E | 9
No or Low Dispersing Air
Manifolded dispersing air pressure set too low: adjust.
Air hose is kinked or cut: repair or replace.
Spray tip is clogged: clean or replace.
Spray tip is damaged: replace.
Air in Liquid Line
Fluid line is not properly attached to pump: replace hose or fitting.
Injector seal is failing: rebuild or replace.
Liquid Drains from Spray Tip
Injector check valve is failing: rebuild or replace.
Liquid line in single point nozzle assembly is damaged or disconnected: replace
8 T60A Posi-pump Troubleshooting
No Liquid
Pump is turned off: turn liquid adjustment screw counterclockwise.
Pump is seized: remove, clean, and rebuild.
Reservoir is empty: fill.
Air pressure is too low: adjust to over 60 PSI.
Bubbles from Injectors
Air seals are leaking: replace.
Exit fitting is leaking: replace.
Liquid Drains from Injector Outlet
Exit fitting is leaking: replace.
Evacuation valve is ineffective: clean or replace.
Biaxial hose is trimmed incorrectly: be sure hose is cut straight with no burrs or
deformities.