Do you have a question about the American Sensor CO810 and is the answer not in the manual?
Categorizes symptoms by exposure severity: mild, medium, and extreme.
Lists areas where the detector should not be placed due to environmental factors.
Specific steps for installing plug-in models into a wall outlet.
Instructions for rotating the plug for vertical installation in horizontal outlets.
Steps for qualified personnel to connect the hardwire model to electrical systems.
Details the function and color of the Power and Warning/Alarm indicator lights.
How to understand the display readings for normal, low, and high CO levels.
Guidance on actions to take based on digital display alerts or warnings.
Actions based on whether a full alarm or low-level warning repeats after reset.
How to reset the detector once a carbon monoxide issue has been resolved.
Steps if a full alarm or low-level warning recurs after reset.
Process to reset the detector after a CO problem is fixed.
Specifies CO concentrations and timeframes for full alarm activation.
Details CO concentrations and timeframes for low-level warning activation.
How making homes more airtight affects indoor air quality and CO concentrations.
Guidance on keeping equipment areas clean and preventing blockages.
Ventilation considerations when enclosing furnaces or water heaters.
Identifying signs of potential CO hazards like poor burner flames or gas smells.
Recommendations for professional checks and proper installation of appliances.
| Sensor Type | Electrochemical |
|---|---|
| Alarm Volume | 85 dB at 10 feet |
| Test/Silence Button | Yes |
| LED Indicator | Yes |
| Operating Temperature | 40°F (4.4°C) to 100°F (37.8°C) |
| Warranty | 5 years |
| Operating Humidity | 10% to 95% non-condensing |
| Alarm Sound Level | 85 dB |
| Compliance | UL 2034 |