AHow should you
install the Hardwire Models?
t/FOR
120 VOLT HARDWIRE
MODEL!5 CO810
WmING: Your Carbon
Monoxide Detector is to be
mounted onto a junction box on the wall or ceiling. These
units are fbr permanent connection only and should be
irxdled by
Qualified Service Personnel only. Do not connect
wires co an AC outlet, extension cord, or power cord and
attachment
plug. Do
not connect to an AC outlet that is con-
trolled
by a wall switch. These units operate on 120 Volt AC.
l
Hardwire
Installation Instructions
for
Service
Personnel
Simply attach your unit
to any standatd
120
Volt wiring
system utilizing the ho wires and one of the electrical
federal &ctricaf and building code standards at all times.
Mount your Carbon Monoxide Detector near the sleeping
areas of the
home. To install
the Detector, please follow
these steps:
1
.
2
.
Makekre the AC power to the junction box is turned
off
at the
Fuse Box or
Service
Panel
before installation.
Install the appropriate round or box mounting
plate
(supplied) to the junction box using the two 5/E? inch
screws (supplied). Be sure to pull the white (neutral)
wire and black (live) wire fi-om the junction box
through the mounting plate center.
Round Mounting Plate
SMARTHOME.COM(TM) 1-800-SMART-HOME 949-221-9200 http://www.smarthome.com