EasyManua.ls Logo

American Standard Selectronic 606B.X10 - AC VERSION (PK00.PAC POWER KIT); HARD-WIRED AC POWER KIT (PK00.HAC)

American Standard Selectronic 606B.X10
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
M965643 Rev. 1.6 (11/16)
Fig. 10a
2
2
Fig. 10
3
2
10
10
1
4
5
6
11
Fig. 10a
2
2
Fig. 10
3
2
10
10
1
4
5
6
11
12
11
ELECTRICAL
OUTLET
BLACK & WHITE
POWER
CONNECTIONS
CONNECTOR NOT
USED IN THIS
INSTALLATION
7
Fig. 10b
8
AC VERSION (PK00.PAC POWER
KIT); Fig. 10, 10a
1. Connect one end of the rst 27" EXTENSION CABLE (1)
to SENSOR CABLE (5). Connect the other end of the 27"
EXTENSION CABLE (1) to the SOLENOID CABLE (3).
Fig.10.
2. Connect AC POWER SUPPLY (2) to the SINGLE AC
ADAPTER (10). Fig.10.
3. Connect the second 27" EXTENSION CABLE (1) to
the SINGLE AC ADAPTER (10), and the other end
of the 27" EXTENSION CABLE (1) to available
SENSOR CABLE (6). Fig.10.
4. Plug AC POWER SUPPLY (2) into outlet. Fig.10a.
5. Place SINGLE AC ADAPTER (10) into electrical box.
FOR HARD-WIRED VERSION
(PK00.HAC POWER KIT) Fig. 10b
6. Contractor to supply ELECTRICAL BOX (11).
7. Connect black and white power line connections to
HARD-WIRED AC TRANSFORMER (12) and mount
into ELECTRICAL BOX (11). Fig. 10b.
NOTE: CONNECTOR LOCKING DEVICE not used
for AC installation.