Service Facts
© 2005 American Standard Inc. All Rights Reserved
NOTICE: Since the manufacturer has a policy of continuous product and product data improvement,
it reserves the right to change design and specifications without notice.
B - FURNACES
PRODUCT SPECIFICATIONS
1
MODEL
TYPE
RATINGS 2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
*UY080R9V3W
Upflow / Horizontal
52,000
48,000
80,000
73,000
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 156
Gas Furnace – Var. Speed Blower –
Var. Speed Inducer – Two Stage Heat –
Direct Vent
Models: * - First letter may be “A” or “T”
*UY060R9V3W *DY060R9V3W
*UY080R9V3W *DY080R9V3W
*UY100R9V4W *DY100R9V4W
*UY120R9V5W *DY120R9V5W
Page B-651-438
W.M. 1/05R
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
DISCONNECT POWER BEFORE SERVICING
WARNING
*UY060R9V3W
Upflow / Horizontal
39,000
37,000
60,000
56,000
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 146
*UY100R9V4W
Upflow / Horizontal
65,000
60,000
100,000
93,000
35 - 65
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 20x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
13.5
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
197 / 185
*UY120R9V5W
Upflow / Horizontal
78,000
72,000
120,000
112,000
40 - 70
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 24x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
6
115/1/60
15.2
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 193
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
X341119P12
Question and Answer IconNeed help?

Do you have a question about the American Standard TDY100R9V4W and is the answer not in the manual?

Summary

Product Specifications

Model and Specification Overview

Overview of furnace models, ratings, and key specifications.

Critical Servicing Safety Warning

Essential safety instruction to disconnect power before servicing.

Safety Guidelines and Warnings

Carbon Monoxide Poisoning Hazard

Steps to prevent CO poisoning from venting system issues.

Fire and Explosion Hazards

Warnings on gas leak testing and risks from improper servicing.

Electrical and Bodily Injury Risks

Hazards from high voltage, moving fans, and combustible gas.

Grounding and Polarity Precautions

Instructions on proper grounding and polarity for safe operation.

Operational Sequences and Timing

Heating Cycle Operation

Step-by-step process for initiating and progressing through heating stages.

Indoor Blower Timing and Control

Details on blower timing, fan-off delays, and cooling delay options.

Periodic Servicing and Inspection

General Furnace Inspection

Annual checks of flue areas, vent connectors, and furnace support.

Component Maintenance Procedures

Guidelines for filter replacement, blower cleaning, and igniter handling.

Burner and Heat Exchanger Servicing

Procedures for cleaning burners and inspecting heat exchangers.

System Safety and Condensate Management

Safety notes and checks for condensate drain systems.

Integrated Furnace Control Diagnostics

Red LED Error Flash Codes

List of error codes indicated by the red LED on the IFC.

Schematic Diagram Overview

Overview of the furnace's electrical schematic diagram.

Integrated Furnace Control Diagnostic Details

Green LED Status Codes

Interpretation of green LED states for operational status.

Fault Code Recovery and Reset

Procedures for clearing fault codes from the control module.

American Standard TDY100R9V4W Specifications

General IconGeneral
ModelTDY100R9V4W
TypeGas Furnace
Heating Capacity100, 000 BTU
AFUE95%
Blower TypeVariable Speed
Fuel TypeNatural Gas
StagesTwo-Stage
Blower MotorECM
Warranty10-Year Limited Warranty

Related product manuals