–54–
DIALER
PROGRAMMING(
✱
40 –
✱
44 and
✱
47 –
✱
50)
✱
40 PABX ACCESS CODE (See Box at Left) | | | | |
Enter up to 6 digits if PABX is needed to access an outside line. If
fewer than 6 digits are needed to be entered, exit by pressing [
✱
] and
next field number (e.g., 41). To clear entries from field, press
✱
40
✱
.
Fields
✱
40,
✱
41,
✱
42:
Enter up to the number of
digits shown. Do not fill
unused spaces.
Enter 0–9,
# + 11 for
✱
# + 12 for #
# + 13 for a pause
(2 seconds)
✱
41 PRIMARY PHONE No. (See Box at Left)
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. If fewer than 20 digits entered, exit by pressing
[
✱
]
and next field number (e.g., 42). To clear entries from field, press
✱
41
✱
.
Note: Back-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number (field
✱
42).
✱
42 SECONDARY PHONE No. (See Box at Left)
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. If fewer than 20 digits entered, exit by pressing
[
✱
]
and next field number (e.g., 43). To clear entries from field, press
✱
42
✱
. See back-up reporting note for field
✱
41. If using the pager
feature, enter the pager phone number here.
For Fields
✱
43 and
✱
44:
Enter digits 0–9; # +11=B; #
+12=C; # +13=D; # +14=E; or
# +15=F.
Enter [
✱
]
as the fourth digit if a
3-digit account number (for 3+1
dialer reporting format) is used.
Enter 0 as the first digit of a 4-
digit account number for Nos.
0000–0999. Exit field by
pressing [
✱
]
(and press next
field number) if only 3 digits are
used.
To clear entries from field,
press
✱
43
✱,
or
✱
44
✱.
See blank Programming Form
for examples of Account No.
entries.
✱
43 PRIMARY SUBS ACCOUNT. No. | | |
See box at left.
✱
44 SECONDARY SUBS ACCOUNT. No. | | |
See box at left.
✱
47 PHONE SYSTEM SELECT 3
If Central Station Receiver is not on WATS line:
0 = Pulse Dial
1 = Tone Dial
If Central Station Receiver is on WATS line:
2 = Pulse Dial
3 = Tone Dial
✱
48 REPORT FORMAT 7 7
0 = 3+1; 4+1 ADEMCO Low Speed Standard Prim. Sec.
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Low Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
Enter
✱
as the 4th digit of
✱
43 and
✱
44, if 3+1 dialer reporting is to
be used.
For an explanation of these formats, see the SYSTEM
COMMUNICATION section.
Note: The maximum number of alarm and alarm restore reports
during one armed period is determined by field
✱
93.

Table of Contents