143ASC200/ASC250
MAINTENANCE MANUAL
2
1
Every 20 Hours or Daily Every 20 Hours or Daily
3.6.8. Cleaning the water separator
Prepare a vessel for draining the settling.
Use your hand to open the drain valve 1. Turn the valve
counterclockwise approximately 31/2 turns until the
valve drops down 25 mm (1 in) and draining occurs
and let fuel drain until clean fuel starts to drain.
! WARNING !
If you drained more than 6 cl (2 ozs) of
fuel, refuel into the fuel filter with hand
pump.
Do not smoke nor use open fire
when working.
Do not drain the separator un-
der running engine.
Catch the drained fuel with sedi-
ments to a suitable container.