EasyManuals Logo

Ampeg SVT-4 PRO Owner's Guide

Ampeg SVT-4 PRO
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
2
Important Safeguards and Precautions:
All Ampeg products are designed for continuous safe operation, as long as common sense is used and steps are taken
to help avoid certain problems. Abiding by the following rules can help prevent damage to your amplifier, yourself and oth-
ers.
The amplifier is equipped with a three-pronged AC power cord. To reduce the risk of electrical shock,
NEVER remove or otherwise attempt to defeat the ground pin of the power cord.
Connect the amplifier ONLY to a properly grounded AC outlet of the proper voltage for your amp.
Avoid sudden temperature extremes, rain and moisture. Also, avoid sudden and intense impact. (If the unit
has been subjected to any of the preceding abuses, have it looked at by an authorized service center.)
NEVER set the amplifier on a support that might give out under its weight.
Always keep the total speaker impedance at or above the rated load.
Unplug the amplifier before cleaning it. NEVER spray liquid cleaners onto the amplifier. Wipe it with a slight-
ly dampened, lint-free cloth to remove dirt and film.
Don’t use the amplifier if it has sustained damage to the chassis, controls, or power cord. Refer the unit to
an authorized service center for inspection.
Amplifiers capable of producing high volume levels are also capable of inflicting permanent hearing loss or
damage, if the exposure to such levels is prolonged. Such damage is progressive and irreversible!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER.
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION
RISQUE D'ELECTROCUTION
NE PAS OUVRIR
ATTENTION: POUR REDUIRE D'ELECTROCUTION NE PAS
ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE N'EST REPRABLE
PAR L'UTILISATEUR. POUR TOUTE REPARATION, S'ADRESSER A UN
TECHNICIEN QUALIFIE.
VORSICHT
ELEKTRISCHE SCHLAGGEFAHR
NICHT OFFENEN
VORSICHT: ZUR MINIMIERUNG ELEKTRISCHER SCHLAGGEFAHR NICHT
DEN DECKEL ABENHMEN. INTERNE TEILE KONNEN NICHT VOM
BENUTZER GEWARTET WERDEN. DIE WARTUNG IS QUALIFIZIERTEM
WARTUNGSPERSONAL ZU UBERLASSEN.
THIS EQUIPMENT HAS BEEN DESIGNED AND ENGINEERED TO PROVIDE SAFE AND RELIABLE OPERATION. IN ORDER TO PROLONG THE LIFE OF THE UNIT AND PREVENT ACCIDEN-
TAL DAMAGES OR INJURY, PLEASE FOLLOW THESE PRECAUTIONARY GUIDELINES:
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN CHASSIS; DO NOT DEFEAT OR REMOVE THE GROUND PIN OF THE POWER CORD; CONNECT ONLY TO A PROP-
ERLY GROUNDED AC POWER OUTLET.
CAUTION: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
CAUTION: NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION: OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND PRESSURE LEVELS CAN CAUSE PERMANENT
HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PROTECTION IS RECOMMENDED IF UNIT IS OPERATED AT HIGH VOLUME. The chart below shows the U.S.
Government Occupational Safety and Health Administration (OSHA) regulations which were in effect at the time of this publication for permissible noise exposure, per 29CRF1910, Table G-16.
According to OSHA, any exposure in excess of those listed above could result in some hearing loss.
"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL"
"REFERREZ-VOUS AU MANUAL D'UTILISATION"
"UNBEDINGT IN DER BEDIENUNGSANLEITUNG NACHSCHLAGEN"
EXPLANATION OF
GRAPHICAL SYMBOLS:
"DANGEROUS VOLTAGE"
"DANGER HAUTE TENSION"
"GEFAHLICHE SPANNUNG"
=
=
SOUND LEVEL dBA DURATION PER DAY
SLOW RESPONSE IN HOURS
90 8
92 6
95 4
97 3
100 2
SOUND LEVEL dBA DURATION PER DAY
SLOW RESPONSE IN HOURS
102 1-1/2
105 1
110 1/2
115 1/4 or less
TABLE OF CONTENTS
Important Safeguards and Precautions . . . . . . . . . . . . . . .2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
The Front Panel Controls and Their Use (English) . . . . .4,5
The Front Panel Controls and Their Use (Spanish) . . . . .6,7
The Rear Panel (English) . . . . . . . . . . . . . . . . . . . . . . . .8,9
The Rear Panel (Spanish) . . . . . . . . . . . . . . . . . . . . . .10,11
Connections: Mono Bridged . . . . . . . . . . . . . . . . . . . . .12
Dual Mono . . . . . . . . . . . . . . . . . . . . . . . .12
Stereo . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Biamp, Full Range and Lows . . . . . . . . . .13
Biamp, Highs and Lows . . . . . . . . . . . . . .13
Biamp With Secondary Amplifier . . . . . . . .13
Some Suggested Settings . . . . . . . . . . . . . . . . . . . . . . . .14
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
System Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . .15
Technical Specifications . . . . . . . . . . . . . . . . . . .back cover
SVT-4 PRO Bass Amplifier

Other manuals for Ampeg SVT-4 PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ampeg SVT-4 PRO and is the answer not in the manual?

Ampeg SVT-4 PRO Specifications

Output Power IconOutput Power
output power rating mono-bridged at 4 ohms1600 Watts
output power rating mono-bridged at 8 ohms1200 Watts
output power rating 2 x at 2 ohms900 Watts
output power rating 2 x at 4 ohms625 Watts
output power rating 2 x at 8 ohms350 Watts
Tone Control Range IconTone Control Range
bass control range±12dB @ 50Hz
midrange control range±15dB @ selected frequency
treble control range+14dB / -19dB @ 5kHz
Graphic EQ IconGraphic EQ
graphic eq level±10dB
graphic eq range 33Hz±15dB
graphic eq range 80Hz±8dB
graphic eq range 150Hz±8dB
graphic eq range 300Hz±8dB
graphic eq range 600Hz±8dB
graphic eq range 900Hz±8dB
graphic eq range 2kHz±8dB
graphic eq range 5kHz±9dB
graphic eq range 8kHz±10dB
Switches IconSwitches
bright switch+6dB @2kHz
ultra high switch+6dB @ 5kHz
ultra low switch+2.5dB @ 50Hz -12dB @ 560Hz +1.5dB @ 5kHz
General Specifications IconGeneral Specifications
signal to noise ratio75dB typical
compression ratio10:1
tube complement12AX7 (3)
Power Requirements IconPower Requirements
domestic power requirements120VAC, 60Hz, 1.4kVA
export power requirements 100/115VAC50/60Hz, 1.4kVA
export power requirements 230VAC50/60Hz, 1.4kVA
Size and Weight IconSize and Weight
width19/17.4”
height with feet5.6”
depth15.5”
weight39.5 lbs

Related product manuals