10
Function Ranges Resolution Accuracy
ACV
400.0mV 0.1mV ± (1.5%+ 5 D)
4.000V 0.001V
± (0.9%+ 5 D)
40.00V 0.01V
400.0V 0.1V
600V 1V
Frequency Response: 50 ~ 500Hz
AC Conversion Type: AC Coupled Average Sensing, RMS
Indication.
Input Impedance: 10M, <100pF.
Overload protection: 600V rms.
Function Ranges Resolution Accuracy
DCV
400.0mV 0.1mV ± (0.7%+ 5 D)
4.000V 0.001V
± (0.6%+ 2 D)40.00V 0.01V
400.0V 0.1V
600V 1V ± (0.7%+ 5 D)
Input Impedance: 10M, <100pF.
Overload protection: 600V rms.
Function Ranges Resolution Accuracy
ohm
400.0 0.1 ± (0.9%+ 5 D)
4.000K 0.001K
± (0.9%+ 2 D)40.00K 0.01K
400.0K 0.1K
4.000M 0.001M
± (1.5%+ 5 D)
40.00M* 0.01M
Open Circuit Voltage: 0.4V
* There is a little rolling less than ± 2%
Overload protection: 600V rms.