Ambient conditions
Temperature range ..........-15°C…55°C
Humidity............................max. 95 % rel.
humidity (31°C)
..........................................max. 45 % rel.
humidity (45°C)
Height above seal level ....0…2000 m
Measuring circuit
category ............................CAT III / 1000 V,
CAT IV / 600 V
Degree of soiling ..............2
Protection class..................IP 64
Safety ................................EN 61243-3,
DIN VDE 0682-401
Dimensions (HxWxD) ........approx.
280 x 78 x 35 mm
Weight ..............................approx. 270 g
(VP-700)
approx. 310 g
(VP-710, VP-720)
Limited warranty &
limitation of liability
AMPROBE instruments are subject to a strict
quality control. However, if a malfunction
occurs during daily use, we offer a guaran-
tee of 24 months (only valid with invoice).
We shall rectify manufacturing or material
defects free of charge, provided the instru-
ment malfunction was not caused by exter-
nal factors and the instrument is returned to
us unopened.
The warranty does not extend to instru-
ments damaged by dropping or incorrect
handling. If malfunctions occur after the
warranty period has elapsed, our factory ser-
vice department will repair your instrument
immediately.
Subject to change !
23