OPERATOR MANUAL
AMSCO
®
Evolution
®
Series Steam Sterilizers
Rev AD 129390199

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Amsco HC-1500 and is the answer not in the manual?

Amsco HC-1500 Specifications

General IconGeneral
BrandAmsco
ModelHC-1500
CategoryLaboratory Equipment
LanguageEnglish

Summary

Service Information

Safety Precautions

Installation Verification

Installation Checklist

Checklist for ensuring correct installation and setup of the sterilizer.

Technical Specifications

Utility Requirements

Specifies electrical, steam, water, and air requirements for sterilizer operation.

Techniques of Sterilization

Control Measure for Verifying Sterilization Process

Methods for verifying sterilization process, including biological indicators and tests.

Techniques of Sterilization for Liquid Cycle

Guidelines and parameters for sterilizing liquids using the liquid cycle.

Component Identification

Sterilizer and Cycle Controls

Overview of key operating controls, valves, and touch screen interface.

Alarm Displays

Information on how alarm conditions are displayed and basic troubleshooting steps.

Sterilizer Operation

Before Operating the Sterilizer

Essential steps and checks to perform before operating the sterilizer.

Preparing Loads for Sterilization Cycles

Guidelines for preparing materials and equipment for sterilization cycles.

Guidelines for Placement of Various Loads

Recommendations for arranging loads within the sterilizer chamber for optimal results.

Prevacuum Sterilizer Cycle

Detailed description of the Prevacuum sterilizer cycle and its settings.

Prevac Cycles

Procedure for running Prevac cycles, including 270°F and 275°F options.

Gravity Cycles

Procedure for running Gravity cycles for instrument trays and fabric packs.

Liquid Cycle

Procedure for sterilizing liquids using the Liquid cycle, including safety warnings.

SFPP Sterilizer Cycles

Description of SFPP cycles for fabric packs and instrument trays.

SFPP Cycles

Procedure for running SFPP cycles, detailing steam flush pulses and time settings.

Test Cycles

Overview of test cycles used to verify sterilizer function at optimum capability.

Dart (Bowie-Dick) Test

Procedure for conducting the Dart (Bowie-Dick) test to document residual air removal.

Vacuum Leak Test

Procedure for testing vacuum integrity of the sterilizer and its piping.

Emergency Manual Exhaust

Procedure for manually exhausting the sterilizer chamber in an emergency.

Cycle and Control Value Programming

Cycle Values

Default factory-set cycle values for AMSCO Evolution sterilizers.

Change Values

Procedure for adjusting cycle values within limited ranges for tailored operation.

Change Cycle Values

Overview of how to access and change cycle parameters like time, temp, and dry time.

Change Cycle Values Procedure

Detailed step-by-step guide for modifying specific cycle operating parameters.

Routine Maintenance

Preventive Maintenance

Guidelines for preventive maintenance and required inspections by qualified technicians.

Troubleshooting

In-Cycle Alarms

Alarms that appear specifically during a sterilization cycle operation.

Too Long In Exhaust

Occurs if chamber does not exhaust to 4 psig within the allotted time.

Too Long In Evacuation

Occurs if chamber does not reach set evacuation level within the allotted time.

Too Long In Air Break

Occurs if chamber does not air break vacuum to 2 inHg within the allotted time.

Under Sterilize Temperature

Occurs if chamber temperature drops below sterilize temperature.

Over Sterilize Temperature

Occurs if chamber temperature exceeds maximum sterilize temperature.

OE/NOE Door Unsealed

Occurs if door seal pressure drops below 5 psig.

Chamber Pressure/Temperature Failure

Occurs if chamber readings are outside normal steam range.

Recorder Deviation Alarm

Occurs if temperature probes read more than 1°F apart.

Steam Utility Failure

Indicates steam supply to the sterilizer is shut off or has failed.

Out-of-cycle Alarms

Alarms that appear when the sterilizer is not processing a cycle.

Sensor Alarms

Alarms related to sensor readings that appear anytime the sterilizer is energized.

Service Procedures