AMSTRAD PC1512 - Resolution Check; Symmetry Check; Write Protect Sensor Check; Head Cleaning

AMSTRAD PC1512
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-7
Resolution
Check
a)
Insert
a
blank
diskette.
b)
Move
the head
to Track
39,
write
1 F and 2F by
the
top
and
bottom heads,
then measure the
average
output
level.
c) The resolution is
higher than
55%,
and
calculations shall be as
follows:
2F output (mV)/1
F output (mV)
x 1 00>55%
Measuring
Conditions
Channel
1-TP1 (10mV/div)
MODE-ADD
Channel
2-TP2 (10mV/div)
Sweep-20ms/div
Trigger—
TP6
2F
average
output
level
Resolution
=
1 F average output
level
95%
or less with
TKO
55%
or more with
TK39
5-8
Symmetry
Check
a)
Insert
a blank diskette.
b)
Move the head
to track and write 1 F
by
the
top
and bottom heads.
Measuring
Conditions
Channel
1-TP5 (0.1V/div) MODE--CH1
Trigger—
INT.CH1 Sweep-0.5ms/div
Slope(+)
T
=
400 ns or less
(If
you
have
individual
spec,
this item
obey
your
spec.)
5-9
Write Protect Sensor
Check
Load and unload a diskette and check
that write protect sensing is definitely made using
Brikon.
5-10
Head Cleaning
Check for
excessive dust or oxidised magnetic iron powders on
the
load
pad
using
such a dentist's
mirror. Clean the heads
using a cloth that produces no flues or an applicator dipped in 91%
isopropyl alcohol. Clean the heads carefully
and remove accumulated dust and oxidised magnetic
iron powders. Wipe the
head using a cloth that produces no flues.
14