Programming
162
MVP-7500/8400 Modero Viewpoint Wireless Touch Panels
Panel Setup Commands
These commands are case insensitive.
Panel Setup Commands
^MUT
Set the panel
mute state.
Syntax:
"'^MUT-<mute state>'"
Variable:
mute state= 0 = Mute Off and 1 = Mute On.
Example:
SEND_COMMAND Panel,"'^MUT-1''"
Sets the panel’s master volume to mute.
@PWD
Set the page flip
password.
@PWD sets the level 1 password only.
Syntax:
"'@PWD-<page flip password>'"
Variables:
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'@PWD-Main'"
Sets the page flip password to 'Main'.
^PWD
Set the page flip
password.
Password level is required and must be 1 - 4.
Syntax:
"'^PWD-<password level>,<page flip password>'"
Variables:
password level = 1 - 4.
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^PWD-1,Main'"
Sets the page flip password on Password Level 1 to 'Main'.
@RPP
Reset the
protected
password.
@RPP resets the protected password to its default (1988).
Syntax:
"'@RPP'"
Example:
SEND COMMAND Panel,"'@RPP'"
Resets the protected Setup page password to ‘1988’.
^VOL
Set the panel
volume.
Syntax:
"'^VOL-<volume level>'"
Variable:
volume level = 0 - 100. 100 is maximum volume setting.
Example:
SEND_COMMAND Panel,"'^VOL-50'"
Set the panel volume to 50.