Questions and Answers

  • L
    Lisa AndrewsAug 2, 2025
    Why is the cuff not inflating on my AND Blood Pressure Monitor?
    • R
      Rachel GravesAug 2, 2025
      If the cuff on your AND Blood Pressure Monitor isn't inflating, it could be due to low battery voltage. You might see a blinking 'LOW BATTERY' indicator, or no indicator at all if the battery is completely drained. Recharge the battery to resolve this issue.
  • M
    Michelle McgeeAug 8, 2025
    How to fix AND Blood Pressure Monitor when nothing appears on the display?
    • T
      Theresa FranklinAug 9, 2025
      If your AND Blood Pressure Monitor displays nothing, even when turned on, the battery may be completely drained. Try recharging it. Alternatively, the battery's lifespan might be over, so consider replacing it with a new one.
  • S
    Shaun TaylorAug 17, 2025
    Why does the battery run out so fast on my AND UM-211 Blood Pressure Monitor?
    • J
      Jeffery AndersonAug 17, 2025
      If your AND Blood Pressure Monitor's battery drains quickly even after recharging, the battery may be worn out. Replacing it with a new one should solve the problem.
  • P
    Paul UnderwoodAug 25, 2025
    What to do if my AND UM-211 readings are too high or low?
    • M
      Michelle GardnerAug 25, 2025
      Inaccurate readings on your AND Blood Pressure Monitor can stem from several factors: * The cuff might not be applied correctly. Make sure it's properly positioned. * Movement during measurement can interfere with accuracy. Remain still and quiet. * Incorrect arm position can also cause issues. Sit comfortably, place your arm on a table with your palm facing up, and ensure the cuff is at heart level. If you have a very weak or irregular heartbeat, the device may struggle to determine your blood pressure.

Summary

Dear Customers

Precautions

Installation/storage location, flammable gases, oxygen environments, temperature, humidity, sunlight, shock, dust, stable location, chemicals, water resistance, electrical fields, shock damage, cuff/hose storage.

Precautions During Use

Confirmation Before Use

Safety, AC adapter use, specified options, cleaning, electrical devices, IV drips, doctor/medical worker use, ambulance/helicopter use, AC adapter connection, newborn/pregnant women, mastectomy, patient arm.

Precautions During Using the Device

Error display, vital signs, air hose, wound, cuff position, measurement without cuff, patient status, peripheral arterial disease, AC adapter cable, wet hands, device maintenance.

Device Usage Notes

Specified Battery Pack

Allowed battery, disposal, AC adapter removal, battery removal for storage, recharging.

Battery Handling

Battery Usage

Using after recharge, liquid leak, heating/breaking battery, shock/pressure, replacement.

Display Symbols and Errors

Symbols Appearing on Display

Measurement in progress, Irregular Heartbeat, Memory, Pressurization, Auscultation, Battery full/low, AC connected/recharging, Errors (Err, CUF, E).

Error Codes and Settings Display

Internal errors (Err E, F, 9), AM/PM display, Pressure settings, Room temperature units.

Using the Monitor

Installing; Changing the Batteries

Steps for battery replacement, cautions for battery use, lifespan, removal.

Operation Modes

Measurement Settings

Measurement with SET Pressure

Setting fixed pressure to avoid re-inflation, selecting pressure values.

Measurements

Selecting the Correct Cuff Size

Importance of correct cuff size, arm size chart, cuff consumables.

Applying the Arm Cuff

Steps for correct cuff placement on the arm, index mark alignment.

Measurement Procedures

Normal Measurement

Step-by-step guide for performing a standard blood pressure measurement.

Advanced Measurement

Auscultation Measurement

Performing measurement with auscultation setting ON, steps for pressurization and exhaust.

Post-Measurement Procedures

Notes for Accurate Measurement

Patient posture, relaxation, effects of stress/food/drink, irregular heartbeat, error conditions, cuff position, environment.

Troubleshooting

Troubleshooting Guide

Common problems, possible reasons, and recommended actions (e.g., no display, cuff not inflating, no measurement).

Maintenance

General Maintenance Advice

Avoiding device damage, contacting dealer, recommended periodic inspection.

Cleaning and Inspection

Cleaning Procedures

Steps for cleaning the device and cuff, disinfectants, cautions.

Technical Data

Device Specifications

Type, measurement method, range, accuracy, temperature unit, power supply, number of measurements, classification.

Immunity Test Details

Specific Immunity Standards

AND UM-211 Specifications

General IconGeneral
Measurement MethodOscillometric
Display TypeLCD
Accuracy (Pressure)±3 mmHg
Cuff Size22-32 cm
Memory FunctionYes
Measurement Range (Pulse)40 - 200 beats/minute
Accuracy (Pulse)±5%
Power Source4 x AA batteries