1
INSTRUCTION MANUAL
HVLP Spray Gun
Be sure to observe warning s and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of
life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
or property damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are
the minimum necessary conditions. Follow national and local regulations regarding fire prevention,
electricity and safety as well as your own company regulations.
Symbol Marking on the Spray Gun:
II 2 G Ex h X
This ANEST IWATA spray gun complies
with 2014/34/EU Directive relating to
equipment and protective systems
intended for use in explosive potentially
atmospheres.
II 2 G Ex h IIB T6 Gb X
T
Amb
+5°C +40°C
Complies
with
European
Directive
Specific
Marking for
Explosion
Protective
Group II
(Surface)
Category
(Zone 1&2)
Type of
Atmosphere
(GAS)
Ignition
Protection
(not applied)
Explosion
Group
(Ethylene)
Temperature
Class
(85°C)
Explosion
Protection
level
(EPL)
Additional
conditions:
Any static
Electricity should
be discharged
and needs to be
diverted to the
ground via a
conductive air
hose not
included.
Ambient
Temperature
Important specifications
Max. Pressure 0.70MPa / 7.0bar / 100psi
Noise level 80dB(A)
Spray condition Recommended
Measuring point 1mbackwards from spray gun, 1.6m height
Max. temperature Atmosphere: 5°C~40°C(41°F~104°F) Air and Fluid: 5°C~43°C(41°F~109°F)
*1.Atomizing air pressure means air pressure at spray gun inlet when trigger is pulled and air flows.
Important
Never connect pressure feeding paint except pressure feed type spray gun.
Main specifications
Model
Type of
feed
Fluid nozzle
Air cap assyMark
Recommended condition
Air consumption
l/min (cfm)
Pattern width
mm (in)
Air & fluid
connection
Mass
g (lbs.)
Nozzle orifice
Φ mm (in)
Mark
*1
Atomizing air
pressure
MPa (bar / PSI)
Air pressure
inside air cap
MPa (bar / PSI)
Fluid output
ml/min
WIDER2L-10G2P
Pressure
1.0(0.039)
W2L WIDER2L-G2
0.20
(2.0/ 28)
0.07
(0.7 / 10)
300
470(16.6)
250( 9.8)
Air
G1/4
(NPS1/4)
Fluid
G3/8
(NPS3/8)
375
(0.83)
-12G2P 1.2 (0.047) 500 300(11.8)
-14G2P 1.4 (0.055) 500 300(11.8)
WIDER2L-2-10G2P 1.0 (0.039)
W2L-2 WIDER2L-2-G2
100
430 (15.2)
330(13.0)
-12G2P 1.2 (0.047) 130 350(13.8)
This manual contains IMPORTANT
WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for
painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with
the requirements stated in this instruction
manual including important warnings,
cautions and operation and correct handling.
Read and understand the instruction
manual, before use and retain for reference.
Fluid nozzle Fluid needle assy combination
Model Fluid nozzle Fluid needle assy
Orifice Φ mm (in) Mark Mark
WIDER2L-10G2P Φ 1.0 (0.039) / W2L / 10
12H WIDER2
WIDER2L-12G2P Φ 1.2 (0.047) / W2L / 12
WIDER2L-14G2P Φ 1.4 (0.055) / W2L / 14 15HWIDER2
WIDER2L-2-10G2P Φ 1.0 (0.039) / W2L-2 / 10
12H WIDER2
WIDER2L-2-12G2P Φ 1.2 (0.047) / W2L-2/ 12

Other manuals for Anest Iwata WIDER2L-10G2P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anest Iwata WIDER2L-10G2P and is the answer not in the manual?

Anest Iwata WIDER2L-10G2P Specifications

General IconGeneral
BrandAnest Iwata
ModelWIDER2L-10G2P
CategoryPaint Sprayer
LanguageEnglish

Related product manuals