ii Smart-UPS® VT 10-30 kVA, 208/220 V and XR Battery Enclosure Operation Manual 990-1599B
Display Messages/Troubleshooting . . . . . . . . . . . . . . . . . . . . . 17
Display messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Front Panel Removal/Installation . . . . . . . . . . . . . . . . . . . . . . . 20
Front Panel removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Total-Power-Off Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Restart Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Voltage confirmation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Mechanical Bypass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Mechanical Bypass Lever . . . . . . . . . . . . . . . . . . . . . . . . . 25
Turn into mechanical bypass . . . . . . . . . . . . . . . . . . . . . . . 25
Switch into normal operation (from mechanical
bypass operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Network Management Card with Environmental Monitor. . . . . 27
Network Management Card replacement . . . . . . . . . . . . . . 27
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
General safety prior to module replacement . . . . . . . . . . . . 28
Battery Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Removal and installation of Battery Locks (if applicable) . . . . 29
Battery Module removal . . . . . . . . . . . . . . . . . . . . . . . . . . 30
How to install a Battery Module . . . . . . . . . . . . . . . . . . . . 30
How to Obtain Replacement Parts . . . . . . . . . . . . . . . . . . . . . . 32
Orderable parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Maintenance Bypass Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Operation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Other manuals for APC Smart-UPS VT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the APC Smart-UPS VT and is the answer not in the manual?

APC Smart-UPS VT Specifications

General IconGeneral
Noise level55 dB
Output power24000 W
Input frequency40/70 Hz
Maximum current41 A
Output power capacity30 kVA
Emergency Power Off (EPO)Yes
Battery typeVRLA
Dimensions (WxDxH)559 x 813 x 1499 mm
Nominal input voltage400 V
CertificationC-tick, CE, EN 50091-2, EN/IEC 62040-3, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, ISO 9001, VFI-SS-112
Product colorBlack
Battery recharge time5 h
Operating altitude0 - 999.9 m
Non-operating altitude0 - 15000 m
Storage temperature (T-T)-15 - 45 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code85078000
Weight and Dimensions IconWeight and Dimensions
Weight629090 g
Package weight660000 g