20
5) Check for leaks!
6) Drain the first tank of water (through faucet) to flush out the new membrane! The 2
nd
tank
of water is ready for use.
Fig. 14A
Fig. 14B
How to Replace Stage-5 Carbon Filter:
Replace this last filter at the same time you replace the stage-4 membrane.
1) Remove the OLD filter: See Fig.14 A. Disconnect the output tubing from point H. Remove the
T-fitting from filter’s Left hand port. (point J). Discard the used filter.
2). The new Stage 5 carbon will come with two end plugs on the stage 5 filter that has to be
removed before inserting the tubing. Please refer to Fig. 1A on page 4 for removal instruction.
3) Use some mild bleach solution to rinse the Tee-Fitting and Tubing end. This is to prevent
contamination.
4) Connect the Tee-Fitting to point J and pure water output tubing to point H. Make sure the
“FLOW on the filter is pointing to the pure water output direction. Only this filter change
needs bleach sanitizing. Do Not apply chlorine/ bleach in anyway to Membrane for it will
damage the membrane!
5) Check for leaks!
* * * End Filter Change Section * * *