2
FIGURE 1 – Dimensions of the Model 5000 Electronic Air Cleaner
© Research Products Corporation 2008
31" with Door
28-1/8" without Door
12"
24-5/8"23-7/8"
15-1/2"
17-3/4"
21"
19-5/8"
90-1346
SPECIFICATIONS
TABLE 1 – Initial Airflow Resistance (inches w.c.)
Model
Airflow (CFM)
1000 1200 1400 1600 1800 2000
5000
.10 .14 .17 .21 .25 .29
Electrical – Voltage:
Door: 120 VAC ± 15% @ 50/60 Hz
Control: 18-30 VAC
Electrical – Current/Power:
Door: Consumes less than 50 watts with high voltage active.
Control: 2A maximum low-voltage current for fan control
0.3-0.4 µm Particle Filtration Efficiency @ 347 fpm: 94%
Replacement Media: Model 501
Airflow Capacity: up to 2000 CFM maximum
Max. Equipment Weight:
Cabinet will support 400 lb. static load
Air Cleaner and LED Base Operating Environment:
Temperature: 32°F – 140°F
Humidity: 0-90% non-condensing
Air Cleaner Control Operating Environment:
Temperature: 20°F – 120°F
Humidity: 0-90% non-condensing
Do not wire the Control to EAC terminals of HVAC system.
These terminals are 120 Volts and will damage the Air
Cleaner Control.
CAUTION
DIMENSIONS